ArchiTech Cylindrical Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions 

PROXIMITY READER INSTALLATION 

 

Find the reader type provided, either rectangular or oval.  If you have a 

Rectangular Proximity Reader

, go to step 15.  If 

you have an 

Oval Proximity Reader

, go to step 14 below. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

14. OVAL PROXIMITY READER INSTALLATION

 

 
 

If you have a "

Rectangular

Proximity Reader

, go to step 15. 

 

 

Note that the 

Oval Mounting Plate

 is symmetrical, and therefore has no "top" or "bottom". 

 

14A.  INSTALL THE "OVAL RUBBER GASKET" AND THE 

"OVAL MOUNTING PLATE"  

 

See Fig. 14A.  Place the 

Oval Rubber Gasket 

(with its 

attached 

Oval Mounting Plate

) against the door sur-

face, over the 5/8" diameter thru-hole that was drilled 
into the door in step 9C. 

 

 Secure 

(

snug-tight only, do not over-tighten

) using the 

two Phillips Pan Head screws appropriate for the door 
type as follows:   

 



For Metal Doors:

  #6-32 

x 1/2" long Type F thread 
cutting Phillips head (part 
#SC212); 



For Wood Doors:

      #6  x 

1/2" long Type A Phillips 
head (part #SC265) 

 

 Again, 

do 

NOT 

over-tighten these screws; over-

tightening will cause undesired deformation of the 

Rubber Gasket

 
 

FIG. C:  OVAL PROXIMITY READER 

(GO TO STEP 14 BELOW) 

FIG. D:  RECTANGULAR PROXIMITY READER 

(GO TO STEP 15) 

Option 1 

Option 2 

FIG. 14A:  "OVAL MOUNTING PLATE" (WITH LEFT AND 

RIGHT "TABS") AND THE ATTACHED  

"OVAL RUBBER GASKET" 

Oval Mounting Plate 

Oval Rubber 

Gasket 

Left Tab 

Right Tab 

OVAL 

Thru-Hole 

DO NOT

 

USE

 

POWER

 

DRILLS

 

OR

 

POWER

 

SCREWDRIVERS

 

WHEN

 

INSTALLING

 

THE

 

P

ROXIMITY

 R

EADER

 !   

Содержание Architech

Страница 1: ...nted Networx Control Unit mounted on the inside protected door surface The Cylindrical Lock Motor Wire can be routed within hollow metal doors with solid wood doors this Cylindrical Lock Motor Wire ca...

Страница 2: ...door surface either the long or short side of the door 2 PREP DOOR FOR CYLINDRICAL LOCK If not done already use standard door prep kit tools and the instructions included with the cylindrical lock to...

Страница 3: ...E OF LEVER as shown on the template Tape the template in place 4 MARK TEMPLATE PROXIMITY READER HOLES On the outside door surface mark the two holes for the Proximity Reader mounting screws Mark the c...

Страница 4: ...he mark made for the Door Contact Sensor in the previous step This tape signifies the height from the floor of the Door Contact Sensor 6B Close the door Transfer this height to the door jamb with a li...

Страница 5: ...ARK TEMPLATE SURFACE MOUNTED NETWORX CONTROL UNIT HOLES On the inside protected door surface mark the two Control Unit Mounting Plate Fig 8 holes using the correct mark ings printed on the template if...

Страница 6: ...ce drill the two pilot holes for the Control Unit Mounting Plate mounting screws NOT thru holes Drill only into the in side door surface 9C Use 5 8 drill bit 5 8 diameter thru hole Drill straight thro...

Страница 7: ...Type B contact below right image Drill a 3 8 hole 7 8 deep into the jamb marked in step 6 For Hollow Metal Jambs Use either a 3 4 or 3 8 bit depending on Door Contact Magnet Type A or Type B to drill...

Страница 8: ...door Skip to step 12E on page 13 Option 2 If for some reason you do not wish to run wires through a hollow metal door route the Cylindrical Lock Motor Wire behind the Wir ing Plate HW1945 The wire run...

Страница 9: ...11A Install the latch and secure with screws provided 11B From the outside unprotected side of the door insert the Cylindrical Lock Body into the 2 1 8 diameter door chas sis hole standard ASA 161 doo...

Страница 10: ...e a level to ensure the Wiring Plate is vertical use a pencil to mark its two mounting holes in the door surface 11E Drill the two pilot holes for the Wiring Plate mounting screws NOT thru holes using...

Страница 11: ...ted on the side of the Cylindrical Lock Body that is fur thest from the latch Therefore this Alignment Puck is de signed to shift the Jig to align with the location of the Cylindrical Lock Motor Wire...

Страница 12: ...ontal then clamp the Jig in place temporarily cushion the clamp s with shims or other material to prevent damaging the door surface as shown in Fig 12BB 12C DRILL HOLE WITH DRILL JIG Insert supplied 1...

Страница 13: ...location corre sponds with the part of the Cylindrical Lock Body where the motor wire and the 2 1 8 diameter hole will meet Fig 12D shows a close up of this notch shown from the inside protected side...

Страница 14: ...e Cylindrical Lock Motor Wire plug sleeve color is yellow Secure the Cylindrical Lock with the mounting hardware provided See the installation instructions provided with the Cylindrical Lock for compl...

Страница 15: ...gainst the door sur face over the 5 8 diameter thru hole that was drilled into the door in step 9C Secure snug tight only do not over tighten using the two Phillips Pan Head screws appropriate for the...

Страница 16: ...protected side of the door Do not pinch wires 14C INSTALL OVAL PROXIMITY READER COVER The Oval Proximity Reader cover snaps into place as follows a Hook the Reader on the Left Tab of the Mounting Pla...

Страница 17: ...ews appropriate for the door type as follows For Metal Doors 6 32 x 1 2 long Type F thread cutting Phil lips head part SC212 For Wood Doors 6 x 1 2 long Type A Phillips head part SC265 Again do NOT ov...

Страница 18: ...he inside protected door surface in step 8 See Fig 16 to determine which end is the TOP Place the Control Unit Mounting Plate against the inside protected door surface and secure using the two Phillip...

Страница 19: ...k Body 18 CONNECT THE BATTERY PACK See the above Fig 17 for the location of the Battery Pack socket Place the Battery Pack into the rear of the Surface Mounted Networx Control Unit with the flat side...

Страница 20: ...unted Networx Control Unit into the top of the Control Unit Mounting Plate and press the bottom until flush with the door surface b Insert the Dog Point screw into the bottom of the Surface Mounted Ne...

Страница 21: ...21 ArchiTech Cylindrical Lock Surface Mounted Networx Control Unit Mounting and Installation Instructions NOTES...

Страница 22: ...ArchiTech Cylindrical Lock Surface Mounted Networx Control Unit Mounting and Installation Instructions 22 NOTES...

Страница 23: ...23 ArchiTech Cylindrical Lock Surface Mounted Networx Control Unit Mounting and Installation Instructions NOTES...

Страница 24: ...s or deterioration due to the use of paints solvents or other chemicals This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or w...

Отзывы: