Network Electronics SDI-EO-D15 Series Скачать руководство пользователя страница 1

Rev. 1

Network Electronics ASA, Hinderveien 4, 3204 Sandefjord, Norway, Tel.:+47 33 48 99 99 Fax: +47 33 48 99 98
E-mail: [email protected] - Web: http://www.network-electronics.com

Technical specifications are subject to be changed without notice

1

USER MANUAL

SDI-EO-D15xx.xx

SDI Fiber Optical Converter

for

Dense Wavelength Division Multiplexing

(DWDM)

Network Electronics ASA

Hinderveien 4

N-3204 Sandefjord, Norway

Phone: +47 33 48 99 99

Fax: +47 33 48 99 98

e-mail: [email protected]

www.network-electronics.com

Содержание SDI-EO-D15 Series

Страница 1: ...work electronics com Technical specifications are subject to be changed without notice 1 USER MANUAL SDI EO D15xx xx SDI Fiber Optical Converter for Dense Wavelength Division Multiplexing DWDM Network Electronics ASA Hinderveien 4 N 3204 Sandefjord Norway Phone 47 33 48 99 99 Fax 47 33 48 99 98 e mail support network electronics com www network electronics com ...

Страница 2: ...ice 2 Revision history The latest version is always available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 1 0 02 01 08 RS T622 EO D15xx xx no longer available 0 C 01 05 08 RS Product release C B 01 03 23 RS Included information on the T622 EO D15xx xx module B A 01 03 ...

Страница 3: ...al specifications are subject to be changed without notice 3 Index Revision history 2 1 General 4 2 Specifications 5 3 Connector module 6 3 1 Applying signals to the connector module 6 4 Module status 7 4 1 GPI Module Status Outputs 7 4 2 Front Panel Status Monitoring 8 5 Laser safety precautions 9 Declaration of conformity with CE 10 General environmental requirements for flashlink equipment 10 N...

Страница 4: ...o 35dB gain at 200 MHz This will typically result in equalisation of more than 300 m of high quality coax cable at 270Mbps The optical output is made with a DFB laser for wavelengths according to ITU T rec G 692 The products are not sold separately but as parts of a flashlink DWDM system The product is available in 16 versions Part number Wavelength Part number Wavelength SDI EO D1549 32 SDI EO D1...

Страница 5: ...el nom 800mV Connector BNC Electrical Power 5V DC Control Control system for access to set up and module status with BITE Built In Test Equipment Electrical Output Number of outputs 2 Connector BNC Impedance 75 ohm Return loss 15dB 270MHz Signal level SDI nom 800mV Rise fall time typ 650ps Optical Output Transmission circuit fiber Single Mode Light source DFB Laser Optical power 0 dBm Optical cent...

Страница 6: ...ew of the SDI EO C1 connector module 3 1 Applying signals to the connector module The connector module is the same for the SDI EO D and the SDI OE cards Apply the SDI signal to the BNC digital input connection For monitoring purposes there are two digital outputs as well These signals have a loop through function where the SDI signal applied at the digital input is equalised and passed through a d...

Страница 7: ...ng detailed information of the status of the card The functions of the GPI and the LED s are described in sections 4 1 and 4 2 The GYDA SC controller is described in a separate user manual 4 1 GPI Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connec...

Страница 8: ...y by the LED s at the front of the module The LED s are visible through the front panel as shown in figure 4 Text not printed on the front panel Figure 4 Diode overview of SDI EO D The SDI EO D has 3 LED s each showing a status corresponding to the GPI pinning The position of the different LED s is shown in figure 4 Diode state Red LED Green LED No light Status Module is faulty Module is OK Module...

Страница 9: ...n 400 nm to 700 nm A laser beam can be harmful to the human eye depending on laser power and exposure time therefore BE CAREFUL WHEN CONNECTING DISCONNECTING FIBER PIGTAILS ENDS NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER FIBER NEVER USE MICROSCOPES MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBER END USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm Instruments exist to...

Страница 10: ... 1996 with regard to emissions and EN 55103 2 November 1996 with regard to immunity it thereby complies with the Electromagnetic Compatibility Directive 89 336 EEC General environmental requirements for flashlink equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative h...

Страница 11: ...tronics ASA Hinderveien 4 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 11 Notes ...