22.5.1 LWE Settings
Figure 22.5.1.1
– Configurator page, LWE settings
X-Band
When enabled will cause the VDR to record the LWE video sources transmitting X-Band
images. In case there is also an X-Band source connected to a Video Module this setting
can be switched off to disable the X-Band video recording from an LWE source.
S-Band
When enabled will cause the VDR to record the LWE video sources transmitting S-Band
images. In case there is also an S-Band source connected to a Video Module this setting
can be switched off to disable the S-Band video recording from an LWE source
ECDIS
When enabled will cause the VDR to record the LWE video sources transmitting ECDIS
images. In case there is also an ECDIS source connected to a Video Module this setting can
be switched off to disable the ECDIS video recording from an LWE source.
Other
When enabled will cause the VDR to record the LWE video sources from those other than
the above-mentioned sources.