7
Step2. Release the button after the indicator shows fast
red
flashes.
Step3. The indicator will flash
red
20 times
, and the restore is completed.
5-10. Report Configuration
10 seconds after powering on, Z311B will detect battery voltage, if the device report has been previously
configured, it will issue 1 or 2 reports within 1-60 seconds randomly on the device, and thereafter it will report
according to the configuration.
If the device was already bound related report clusterID to report according to configuration, it would issue a
corresponding report (Max! = 0xFFFF) immediately after completed configuration.
Battery voltage report Default: min = 3600s, max = 3600s, reportchange = 0.1,
Battery status report Default: min = 3600s, max = 0xFFFF (off), reportchange = 0.
Report setting table
:
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Change rate≥ Reportable
Change
Change rate
<
Reportable Change
1-65534
1-65534
≠
0
To report per Minimum
interval
To report per Maximum
interval
0
To report per Minimum
interval
To report per Minimum
interval
0
1-65534
≠
0
To report instantly
To report per Maximum
interval
0
To report per second
To report per second
1-65534
0
≠
0
To report per Minimum
interval
No report
0
To report per Minimum
interval
To report per Minimum
interval
0
0
≠
0
To report instantly
No report
0
To report per second
To report per second
Any
65535
Any
Stop reporting
65535
Any
Any
Stop reporting
Note
:
(1) It is not suggested to set:
Min Interval =0,
Reportable Change=0.
Otherwise, ZB311B will report very densely (every second) to block up the network.
(2) Different attributes have different units, please refer to the product specific
instructions for units of reportable change.