Страница 1: ...ZigBeeTM ZigBee Remote User Manual ZigBee Remote Model Z501A Firmware V5 1 Hardware V2 0 ...

Страница 2: ...d Group ZLL Network 6 5 3 Binding HA Network 6 5 4 Store Scene 7 5 5 Control the Device Wirelessly 7 5 6 Sleeping Mode 8 5 7 Wake up Z501A 8 5 8 Battery 9 5 9 Restore to Factory Setting 9 5 10 Rejoin to Network 9 5 11 Report Configuration for Developer Only 9 7 Netvox App Control Interface 12 8 Related Devices 14 9 Important Maintenance Instructions 15 ...

Страница 3: ...nd Z501A will send the alarm message to the command center The Warning Device will send out alarm sound or lighting alert for immediate help What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low...

Страница 4: ...3 2 Product Appearance Indicator Level Up Level Down Toggle IAS Power Switch Power On Power Off ...

Страница 5: ...ant Utilizes 2 4GHz ISM band up to 16 channels Power supply 3V CR2032 button cell battery Operating consumption 38mA Standby consumption 0 8uA Up to 150 meters wireless transmission range in non obstacle space Easy installation and configuration ...

Страница 6: ...erage from a coordinator or a router whose permit join feature is enabled Z501A will be permitted to join the network Step1 Enable the permit join function valid for 60 seconds of a coordinator or a router please refer to Left Front view Right Back view Open the battery cover Battery Holder Insert the battery The battery is installed Install the battery cover ...

Страница 7: ...r sleeping mode if it fails to join network within 3minutes Z501A will wake up every 15 minutes to try to join to network 5 2 Add Group ZLL Network To add the On Off device into a group please follow the steps Step1 Identify the On Off devices which you would like to add Step2 Press and hold for 2 seconds and then press within 2 seconds to send the add group if identify command The group will be e...

Страница 8: ...ress to perform the Dimming down control C Press to perform the toggle control D Press to perform the emergency alarm HA Network After binding with the On Off Level Control cluster devices A Press to control the On Off feature B Press to control the Dimming up Rolling curtain up feature C Press to control the Dimming down Rolling curtain down feature D Press to send the emergency alarm message to ...

Страница 9: ...ping mode B While the device is in the network the sleeping period is 5 minutes it will wake up every 5 minutes to keep online C Once Z501A was joined to a network and by any chance the network is no longer existed or the device is out of the network Z501A will wake up every 15 minutes to find the network it joined before It never keeps in sleeping mode and continues to find its network every 15 m...

Страница 10: ...ration cluster ID 0x0001 Battery voltage attribute ID 0x0020 5 9 Restore to Factory Setting To restore it to factory setting please follow the steps Step1 Power off Z501A Step2 Press and hold both and and then power on Z501A Step3 After the indicator flashes 20 times reboot Z501A to complete the restore 5 10 Rejoin to Network When the router device is not working in the network Z501A will immediat...

Страница 11: ...o report per Maximum interval 0 To report per Minimum interval To report per Minimum interval 0 1 65534 0 To report instantly To report per Maximum interval 0 To report per second To report per second 1 65534 0 0 To report per Minimum interval No report 0 To report per Minimum interval To report per Minimum interval 0 0 0 To report instantly No report 0 To report per second To report per second An...

Страница 12: ...06 Power Configuration 0x0001 Identify 0x0003 Identify 0x0003 Groups 0x0004 Scenes 0x0005 Level Control 0x0008 ZLL Commissioning 0x10000 ZLL Commissioning 0x10000 Commissioning 0x0015 IAS ACE 0x0501 Poll Control 0x0020 Diagnostics 0x0B05 Attributes of the Basic Information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03...

Страница 13: ...O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M 0Xe001 NetvoxInternalAppl icationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x28 O 0Xe002 NetvoxInternalDateCode Character string 0 16 bytes Read only 20140523 O 0x4000 SW build id Character string 0 16 bytes Read only M 7 Netvox App Control Interface 1 After joining in Netvox App system device IEEE address will show up in device m...

Страница 14: ...device to be bound such as wireless ZC07 dimmable LED bulb 1 and then click on the upper right corner to bind before binding operation make sure the device is in the activated state if the device is in sleep mode users need to activate the device To unbind touch and hold the bound device column till unbind shows up click unbind as shown below 4 Click Level Control Switch into the basic information...

Страница 15: ...ngs About Device interface to switch interfaces to check detail information of the device As shown below 8 Related Devices Devices which are related to Z501A Z501C ZigBee Remote ZB02C ZigBee Switch Z806 ZigBee Output Unit ...

Страница 16: ...ely hot temperatures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do not paint the devic...

Отзывы: