5
4.5 Turn on Permit-join Function
After the device joins the network, you can press shortly the “Binding key” to enable the coordinator in the
network and the allowed function of all routing devices, allowing time is set to be 60 seconds. If it needs to be
turned off immediately, it only needs to be short again within 60 seconds, press the “Binding key”.
4.6 Activate the Device
The device is battery powered and is designed to enter sleep mode when not transmitting. Sometimes you would
need to collect attribute data during the installation and during the deployment process, you need to force the
device to enter active mode.
Operation:
Hold press the binding key and emergency button together until the red light flashes twice then release the key.
The device should automatically broadcast its own short address and IEEE address. Z307 will stay active for 2
minutes.
Note: turn on interval after powering on is 5 min by default setting.
4.7 Low power Notification
The operating voltage of Z307 is between 3.2 to 4.2VDC.
When the battery is bellow operating voltage 3.2V, the red indicator on Z307 will flash once. The device will
broadcast low power notification to the network and also sends this battery status to the enrolled CIE device.
4.8 Restore to Factory Setting
Z307 is capable of storing and saving includes network information. If you wish to remove Z307 from an exited
network, you would need to clear the information and restore to the factory setting; or if you wish to join Z307 to a
new network, a restore to factory default is required.
Operation:
Step 1. Press and hold both binding key and setting key for 5 seconds till the red indicator flashes quickly and the
releases.
Step 2. Red indicator flashes 20 time to restore the device to factory setting.