background image

 

 

4.3 Automatic Zone Registration (enrollment)

 

Z307 is a zone device in the security system. Soon after the network join, the next step is to enroll itself into a CIE 

(Control and Indicating Equipment) –the security system device, to validate Z307 zone alarm feature. The 

registration will take place automatically soon after the device joined to the network.   

*notes: a CIE security system will normally embedded within a device (i.e. a Netvox Z201B coordinator) or it 

could be a stand-alone CIE device.   

 

Observing security system (CIE) registration:     

To ensure enrollment is successful or not, simply read the indicator light flashes. 

(1) Right after the network join, Z307 will send an enrollment request to the air. If there is CIE and it has enrolled 

the red indicator will flash 6 times. The red indicator light flashes 4 times if enrollment failed. 

(2) For any reason that Z307 has failed being registered, when fall even happen at anytime Z307 will initiates the 

enrollment process. The indicator will flash the same as that described in (1). 

 

 

4.4 Emergency and Position System   

How is Z307 triggered 

Z307 can be trigger alarm through emergency button and body falling.   

 

Emergency 

At the event of emergency, the user may press the emergency button once, the device vibrates once while it sends 

alarm signal to the security system for strobe light or siren alert. 

 

Fall Detect 

When the wearer falls, the device vibrates twice indicating fall detected. The device starts 15 seconds countdown 

before it sends fall detect alarm signal to the security system for strobe light or siren alert. The user has 15 seconds 

to cancel the alarm signal to be sent. To cancel the alarm, hold press the emergency button for 2 seconds the alarm 

will be canceled and will not be sent.   

The user may trigger the emergency alarm at any time as they wish. Refer to Emergency in the above. 

 

As described in Automatic Zone Registration section above, Z307 needs CIE to report of fall event. In case that 

Z307 has not been registered to any CIE device, Z306 will attempt to register itself to a CIE device then report its 

alarm message at the time of emergency and fall event. 

 

Position Detect 

Equipment in the alarm at the same time will also report their current location information, in order for  more 

quickly rescue. 

 

Note: The device must be worn on the user's waist, from top to bottom clip on the belt (as far as possible 

perpendicular to the ground). At the same time, the device has a built-in sensitive sensor. When moving the device, 

please use it gently to avoid false triggers. 

Содержание Z307

Страница 1: ...Z307 WirelessTM Wireless Fall Sensor Wireless Rechargeable Fall Sensor User Manual Software V4 0 Hardware V1 2...

Страница 2: ...Automatic Zone Registration enrollment 4 4 4 Emergency and Position System 4 4 5 Turn on Permit join Function 5 4 6 Activate the Device 5 4 7 Low power Notification 5 4 8 Restore to Factory Setting 5...

Страница 3: ...This CIE would then instruct other devices in the network to sound or silent alarm with light strobe Z307 acts as an end device in the network which does not perform permit join other devices to join...

Страница 4: ...d and release the button the device will vibrate once to enter the OFF state Note Power off Z307 when not in use is recommended 4 2 Join to the Network In order for the Z307 to communicate with the Zi...

Страница 5: ...the event of emergency the user may press the emergency button once the device vibrates once while it sends alarm signal to the security system for strobe light or siren alert Fall Detect When the wea...

Страница 6: ...roadcast its own short address and IEEE address Z307 will stay active for 2 minutes Note turn on interval after powering on is 5 min by default setting 4 7 Low power Notification The operating voltage...

Страница 7: ...d to normal operating status To prevent this unwanted power consumption we recommend that users manually power off the device 4 10 Battery Charging The device is built in 3 7V lithium rechargeable bat...

Страница 8: ...rance 5 ZigBee Description 1 End Point s 0x01 2 Device ID IAS Zone 0x0402 3 Cluster ID which EndPoint supports Status indicator red Network indicator green A201 Infrared sensor A201Charging indicator...

Страница 9: ...bit integer 0x00 0xff Read only O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 53 O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xff Read only 20 O 0x0004 ManufacturerName Characte...

Страница 10: ...information Click the icon to enter the state of Figure 5 2 Fig 5 1 Fig 5 2 2 Click the red box in Figure 5 2 above the settings section configure whether to open the alarm sound Click to enter the c...

Страница 11: ...10 3 When an alarm occurs the warning message shown in FIG 5 5 Fig 5 5 7 Related Devices A201 Wireless Charger A201 Infrared sensor A201Charging indicator DC power input 5V...

Страница 12: ...and causing the housing to deform Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that i...

Отзывы: