7
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. PowerChange=2W.
MaxTime
(MinTime)
MinTime
MinTime
MinTime
0H
15
th
M
30
th
M
45
th
M
1H
2H
Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. PowerChange=2W.
MaxTime
(MinTime)
MinTime
MinTime
MinTime
0H
15
th
M
30
th
M
45
th
M
1H
2H
Remarks:
1. Compare the collected data with the last reported data. If the amount of data change is greater than ReportableChange, the device will report based
on the MinTime interval. If the data change is not greater than the last reported data, the device will report based on the MaxTime interval.
2. For the energy consumption detection device, because the device is a constant power supply device, it is not recommended to set the MinTime
interval value too high in order to obtain the status information in real time. It is recommended to use the default 2 seconds. If users need to control
frequent report recommendations to adjust ReportableChange and MaxTime.
3. After the device sends a packet (regardless of whether the data has changed, such as pressing a button or the maximum time is due), another
MinTime / MaxTime calculation cycle is initiated.
6. Load Property
Rated Load
(
AC
)
** Remark**
Max. Load with LEDs
**Remark**
Max.
Inductive
Load
(
cosφ=0.4
)
Max. Load with
Electric Motors
Overload Protection
with Auto Power
Cutoff
EU Type
:
16A/250V
~
UK Type
:
13A/250V
~
AU Type
:
10A/250V
~
US Type
:
15A/125V
~
LED power is less
than 400W and less
than 8 LEDs
8A/250V
1.5HP/250V
YES
When the detected current exceeds the rated load current range, the device will automatically disconnect the load within 2 seconds after the detection.
collects data
9W
Does not report
collects data
10W
Does not report
collects data
9W
Does not report
collects data
11W
REPORTS 11W
collects data
REPORT 10W
collects data
9W
Does not report
collects data
13W
REPORTS 13W
collects data
12W
Does not report
collects data
14W
Does not report
collects data
REPORT 10W