background image

 

 

Device

 

Device 

Type

 

Report 

Type

 

NetvoxPayLoadData

 

R72632A01 

0x09 

0x0F 

Battery 

(1Byte, Unit:0.1V) 

Nitrogen 

(2Bytes,Unit:1mg/kg) 

Phosphorus 

(2Bytes,Unit:1mg/kg) 

Potassium 

(2Bytes,Unit:1mg/kg) 

Reserved 

(1Byte,Fixed 0x00) 

Uplink: 01090f450014001c004100 

 

Byte 

Value 

Attribute 

Result 

Resolution 

1st 

01 

Version 

01 

2nd 

09 

DeviceType 

09 

3rd 

0F 

ReportType 

0F 

4th 

45 

Battery 

6.9v 

45(HEX)=69(DEC),69*0.1v=6.9v 

5th~6th 

0014 

Nitrogen(N) 

20mg/kg 

0014(HEX)=20(DEC),20*1mg/kg=20mg/kg 

7th~8th 

001C 

Phosphorus(P) 

28mg/kg 

001C(HEX)=28(DEC),28*1mg/kg=28mg/kg 

9th~10th 

0041 

Potassium(K) 

65mg/kg 

0041(HEX)=65(DEC),65*1mg/kg=65mg/kg 

11th 

00 

Reserved 

 

 

5.2 Example of ConfigureCmd 

FPort

0x07 

Bytes 

Var (Fix =9 Bytes) 

 

CmdID 

DeviceType 

NetvoxPayLoadData 

CmdID

– 1 byte 

DeviceType

– 1 byte – Device Type of Device 

NetvoxPayLoadData

– var bytes (Max=9bytes) 

Example of report MaxTime configuration: 

Description 

Device 

CmdID 

DeviceType 

NetvoxPayLoadData 

ConfigReportReq 

R72632A01 

0x01 

0x09 

Reserved 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Reserved 

(5Bytes,Fixed 0x00) 

ConfigReportRsp 

0x81 

Status 

(0x00_success) 

Reserved 

(8Bytes,Fixed 0x00) 

ReadConfigReportReq 

0x02 

Reserved 

(9Bytes,Fixed 0x00) 

ReadConfigReportRsp 

0x82 

Reserved 

(2bytes Unit:s) 

MaxTime 

(2bytes Unit:s) 

Reserved 

(5Bytes,Fixed 0x00) 

(1) Configure device parameter MaxTime = 2min 

Downlink: 0109000000780000000000    // 78 (HEX) = 120 (DEC), 

Device return: 

8109000000000000000000 (configuration successful) 

8109010000000000000000 (configuration failed) 

Содержание R72632A01

Страница 1: ...ology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties...

Страница 2: ...Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 6 Installation 7 7 Information about Battery Passivation 8 7 1 To determine whether a battery requires activa...

Страница 3: ...letely waterproof which greatly facilitates the customer s systematic evaluation of soil conditions LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and...

Страница 4: ...can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayen...

Страница 5: ...seconds success The green indicator remains off fail Fail to join the network Suggest to check the device verification information on the gateway or consult your platform server provider Function Key...

Страница 6: ...The data transmission cycle of the device is subject to the burning configuration and there is no minimum time The value of ReportMaxTime should be greater than or equal to 60 seconds 3 In order to m...

Страница 7: ...2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes Example o...

Страница 8: ...ltiple times to obtain the average value within a small range of a measurement point 2 Buried measurement method Dig a pit with a diameter of 20cm vertically insert the sensor steel needle horizontall...

Страница 9: ...vents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may also lead to voltage delay when the batteries are put into operation and our d...

Страница 10: ...e Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy intern...

Отзывы: