6
5. Data Report
After power on, the device will immediately send a version packet report and the data report including the temperature,
humidity, PM2.5 and voltage.
The device sends data according to the default configuration before any other configuring.
ReportMaxTime: 140mins
* The ReportMaxTime should be greater than ReportType count *Report10
ReportMinTime: 30s (US915, AU915, KR920, AS923, IN865)
120s (EU868)
ReportType count = 1
Note:
(1) The cycle of the device sending the data report is according to the default.
(2) The interval between two reports must be the MaxTime.
(3) ReportChange is not supported by R72616A (Invalid configuration). The data report is sent
according to ReportMaxTime as a cycle. (The first data report is the start to the end of a cycle.)
(4) Data pocket: PM2.5, temperature, and humidity.
(5) The device also supports the TxPeriod cycle configuration instructions of Cayenne. Therefore, the device can
perform the report according to the TxPeriod cycle. The particular report cycle is ReportMaxTime or TxPeriod
depending on which report cycle was configured last time.
(6) It would take
45 seconds
for the sensor to sample and process the collected value after pressing the button,
please be patient.
The device reported data parsing please refer to
Netvox LoraWAN Application Command document
and
Netvox Lora
Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index