5
5. Data Report
The device will immediately send a version packet report along with an uplink packet including temperature ,voltage and PH value.
The device sends data in the default configuration before any configuration is done.
Default setting:
ReportMaxTime:
RA0708/RA0708Y
is 180s
R72608
is 900s
Value must be greater than
ReportMinTime
≧
ReportType count *ReportM 10
,units:
seconds
ReportMinTime: 30s
ReportChange: 0
ReportType count = 1
Note:
(1) The device report interval will be programmed base on the default firmware which may vary.
(2) The interval between two reports must be the Maxtime.
(3) ReportChange is not supported by RA0708_R72608_RA0708Y (Invalid configuration).
(4) Report cycle will be based on ReportMaxTime period when sending data packet (beginning to the end of the first data as a
period).
(5) Data packet: temperature, voltage and PH value.
(6) The device also supports Cayenne's TxPeriod cycle configuration instructions. Therefore, the device can also perform a
report according to the cycle time of the TxPeriod value; and whether the report period is ReportMaxTime or TxPeriod will
be depending on which cycle time is configured last time.
(7) It would take about
35 seconds
for the PH sensor to sample and process the collected PH value if you were to manually
trigger the device by pressing the button, please be patient.
The device reported data parsing please refer to
Netvox LoraWAN Application Command document
and
Netvox Lora Command Resolver
http://www.netvox.com.cn:8888/page/index
Содержание R72608
Страница 11: ...10 15...