background image

                                                                                                                                           

      Model

RA0708_R72608_RA0708Y

 

 

 
 

 

 

 

Wireless pH Sensor 

 

 

 

 

 

 

 

 

 

Wireless pH Sensor 

 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright© Netvox Technology Co., Ltd.

 

This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict 

confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The 

specifications are subject to change without prior notice. 

 

Содержание R72608

Страница 1: ...is document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Страница 2: ...duction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 8 6 1 RA0708 8 6 2 R72608 8 6 3 RA0708Y 9 6 4 PH Sensor Use 9 6 5 PH Sensor Maintenance 11 7 Important...

Страница 3: ...ectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation eq...

Страница 4: ...times Power off Remove power Note 1 Engineering test modes require the burning engineering test software 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor i...

Страница 5: ...tion when power down This function is turned off by default that is it will be re joined every time it is powered on This function can be turned on by the ResumeNetOnOff command At this time each time...

Страница 6: ...8Y Invalid configuration 4 Report cycle will be based on ReportMaxTime period when sending data packet beginning to the end of the first data as a period 5 Data packet temperature voltage and PH value...

Страница 7: ...xTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device Cmd ID Devi...

Страница 8: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 9: ...opriate size cylinder on the main bracket of the solar panel and install the gasket in sequence Lock nut till the solar panel is stable and does not shake 3 Adjust the angle of the solar panel After t...

Страница 10: ...2 Loosen the M5 nut at the bottom of the RA0708Y matte and take the matte together with the screw 3 Insert the power DC plug from the center through hole of the RA0708Y bottom cover and insert it int...

Страница 11: ...10 15...

Страница 12: ...maintained in the above manner the sensor has failed Please replace the sensor 7 Important Maintenance Instruction Your device is a product of superior design and craftsmanship and should be used wit...