4. Set up Instruction 

On/Off 

 

Power On 

Insert batteries. (users may need a screwdriver to open) 

Turn On 

Press and hold the function key for 3 seconds till the green indicator flashes once. 

Turn Off (Restore to factory setting)  Press and hold the function key for 5 seconds and the green indicator flashes 20 times. 

Power Off 

Remove Batteries 

Note 

1.  Remove and insert the battery: the device is in the turn-off state by default. 

2.  After 5 seconds of powering on, the device is in engineering testing mode. 

3.  Every time, after remove and reinsert the battery, the device is in a turn-off state and 

need to turn on again. 

4.  On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor 

inductance and other energy storage components. 

Network Joining 

 

Never Join the Network 

Turn on the device to search the network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

Turn on the device to search the previous network. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network 

Suggest to check the device verification information on the gateway or consult your platform 

server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once 

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode 

 

The device turns on and joins in the 

network 

Sleeping period: Min Interval 

When the reportchange exceeds setting value or the state changes, send a data report according 

to Min Interval 

The device is powered on but not 

connected to the network 

Note: 

1. It is recommended to take out the battery when the device is not in use; 

2. It is recommended to check the device registration information on the gateway. 

Low Voltage Threshold Alarm 

 

Low Voltage 

3.2 V 

 

 

 

 

Содержание R720FLT

Страница 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other pa...

Страница 2: ...of ReportDataCmd 5 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 8 6 Installation 9 7 Information about Battery Passivation 10 7 1 To determine whether a battery requires activa...

Страница 3: ...rent voltage value the current number and status of toilet water tank replenishment and report a current detected data packet Check the water supplement times every 24 hours If the preset times are ex...

Страница 4: ...be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Cayenne L...

Страница 5: ...icator remains off fail Had joined the network Turn on the device to search the previous network The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join th...

Страница 6: ...plenishments in the toilet water tank within 24 hours is abnormal Replenish water count Replenishwatercount is the cumulative make up times of the toilet water tank When the device is powered off clea...

Страница 7: ...2F Replenish water count 2F Hex 47 Dec 9th byte 00 Fault Alarm no alarm 10th byte 00 Tank Leak Alarm no alarm 11th byte 00 Reserved Example of uplink 2 01D4019F00000168010000 1st byte 01 Version 2nd b...

Страница 8: ...000000 configuration failure 2 Read R720 FLT device parameter Downlink 02D4000000000000000000 Device return 82D4003C003C0100000000 device current parameter Description Device Cmd ID Device Type Netvox...

Страница 9: ...le for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Dat...

Страница 10: ...tank leakage detection equipment Step1 Open the toilet water tank cover Step 2 Press the handle gently to drain water until the toilet begins to replenish water Record the water level at this time nam...

Страница 11: ...rding to the installation steps 7 Information about Battery Passivation Many of Netvox devices are powered by 3 6V ER14505 Li SOCl2 lithium thionyl chloride batteries that offer many advantages includ...

Страница 12: ...5 Battery Passivation 7 1 To determine whether a battery requires activation Connect a new ER14505 battery to a resistor in parallel and check the voltage of the circuit If the voltage is below 3 3V i...

Страница 13: ...he battery into the fire to prevent the battery from exploding Damaged batteries may also explode All the above suggestions apply equally to your device batteries and accessories If any device is not...

Отзывы: