background image

 

 

10 

7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If  you  buy  batteries  from  other  than  the  above  four  manufacturers,  then  the  battery  activation  time, activation  current,  and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Содержание R718WB2

Страница 1: ...Wireless 2 Gang Water Leak Detector with Rope Sensor R718WB2 Wireless 2 Gang Water Leak Detector with Rope Sensor R718WB2 User Manual...

Страница 2: ...3 Main Features 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 10 7 1 To determine whether a battery requires activation 10 7 2 How to activate the...

Страница 3: ...ompared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For...

Страница 4: ...ease refer to http www netvox com tw electric electric_calc html On this website users can find battery life of various models in different configurations 4 Set up Instruction On Off Power on Insert b...

Страница 5: ...ion on the gateway or consult your platform server provider Function Key Press and hold for 5 seconds Restore to factory setting Turn off The green indicator flashes for 20 times success The green ind...

Страница 6: ...d The leak detected a change in state and immediately issued a report No leaks status 0 leak status 1 The data report can be decoded by the Netvox LoraWAN Application Command document and http www net...

Страница 7: ...Time Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Example 2 based on MinTime 15 Minutes M...

Страница 8: ...nterval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sen...

Страница 9: ...ver or similar tool to assist in opening the battery cover Waterline Structure Installation Suggestions and Examples Water line up to 300m Water contact alarm recommended at least 3cm line length Aler...

Страница 10: ...9 R718WB Time real time Within 10 seconds Fixing Hook 3cm 3cm Soaking water 3CM Send a Report detection line Water Soaking depth 2mm...

Страница 11: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 12: ...stroy batteries and deform or melt some plastic parts Do not store in a cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do...

Отзывы: