12 

7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If  you  buy  batteries  from  other  than  the  above  four  manufacturers,  then  the  battery  activation  time, activation  current,  and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Содержание R718N3

Страница 1: ...td This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Страница 3: ...T Range 150A 3000A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less than 1A the current is...

Страница 4: ...ess sensor monitoring and notification system to configure sensors view data and set alerts via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low...

Страница 5: ...the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light remains off fail to join the network Fail to Join the Network 1 S...

Страница 6: ...ny configuration is done Default setting Maximum time Max Interval 15 min 900 s Minimum time Min Interval 15 min 900 s CurrentChange 0x0064 100 mA The interval between min time and max time must be th...

Страница 7: ...1 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s CurrentChange 2byte Unit 1mA...

Страница 8: ...iplier 3 7000 10 70000 mA 70A Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleepi...

Страница 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 10: ...ta will be reported regularly according to MaxTime 5 Press the Key of the device to start sampling data and report the data after 3 to 5 seconds Note MaxTime must be set greater than Min Time The thre...

Страница 11: ...t transformer and start the measurement according to the wiring below CT Wiring Schematic Diagram Current direction K L Installation Diagram Screw Fixation Screw Fixation R718N3 Wire to be detected Wi...

Страница 12: ...ssemble the device unless it is required to replace the batteries Do not touch the waterproof gasket LED indicator light function keys when replacing the batteries Please use suitable screwdriver to t...

Страница 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 14: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thr...

Отзывы: