5
The device will immediately send a version packet report along with an uplink packet including hall
sensor status and battery voltage.
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Min Interval = 60 min = 3600s
BatteryChange: 0x01 (0.1V)
Hall sensor status:
When the magnet closes to the Hall sensor, it will report the status “0”
(The distance between the magnet and the Hall sensor is less than 3cm)
When the magnet removes the Hall sensor, it will report the status “1”
(The distance between the magnet and the Hall sensor is greater than 3 cm)
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command
http://loraresolver.netvoxcloud.com:8888/page/index
Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a
data report according to Min Interval.
Low Voltage Warning
Low Voltage
3.2V
5.
Data Report