4.Set up Instruction

 

4.1 Power on and Turn on / off   

 

(1)

 

Power  on

:  insert  batteries:  open  the  battery  cover;  insert  two  sections  of  3.6V  ER14505  AA 

batteries and close the battery cover. 
(2)

 

Turn on

: if the device had never joined in any network or at factory setting mode, after powering 

on,  the  device  is  at  off  mode  by  default  setting.  Press  and  hold  function  key  for  3  seconds  till  the 
green indicator flashes once and release.   
(3)

 

Turn off: 

press and hold function key for 5 seconds till the green indicator flashes quickly and 

release. The green indicator will flash 20 times to show that the device is turned off.         
 
Note:   
1.

 

The interval between shutting down twice or power off/on is suggested to be about 10s to avoid 

the interference of capacitor inductance and other energy storage components. 
2. Do not press function key and insert batteries in the same time, otherwise, it will enter engineer 
testing mode.   

4.2 Join Into LoRa Network   

To join the device into LoRa network to communicate with LoRa gateway. 
The network operation is as following: 
(1)

 

If the device had never joined any network, turn on the device; it will search an available LoRa 

network  to  join.  The  green  indicator  will  stay  on  for  5  seconds  to  show  it  joins  into  the  network, 
otherwise, the green indicator does not work. 
(2)

 

If the device had been joined into a LoRa network, remove and insert the batteries; it will repeat 

step (1).   

4.3 Function Key

 

(1)

 

Press and hold function key for 5 seconds to reset to factory setting. After restoring to   

      factory setting successfully, the green indicator will flashes quickly 20 times.     

(2) 

Press function key to turn on the device which is in the network and the green indicator will flash 

 

      once and the device will send a data report.       

 

4.4 Data Report   

When the device is turned on, it will immediately send a version package.   
Data will be reported once per hour by default setting. 
Maximum time: 3600s 
Minimum time: 3600s (Detect the current voltage value every 3600s by default setting) 
Default reportchange:   
Battery ---- 0x01 (0.1V) 

Содержание R718F2

Страница 1: ...Mode R718F2 Wireless 2 Gang Reed Switch Open Close Detection Sensor Wireless 2 Gang Reed Switch Open Close Detection Sensor R718F2 User Manual...

Страница 2: ...eatures 3 4 Set up Instruction 4 4 1 Power on and Turn on off 4 4 2 Join Into LoRa Network 4 4 3 Function Key 4 4 4 Data Report 4 5 Restore to Factory Setting 5 6 Sleeping Mode 5 7 Low Voltage Alarmin...

Страница 3: ...y dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely us...

Страница 4: ...2 Appearance Fig 1 R718F2 Appearance 3 Main Features Compatible with LoRaWAN protocol Powered by 2 x ER14505 3 6V Lithium AA battery Objects to be detected open close status Easy set up and installati...

Страница 5: ...2 Join Into LoRa Network To join the device into LoRa network to communicate with LoRa gateway The network operation is as following 1 If the device had never joined any network turn on the device it...

Страница 6: ...ce operation of turning off is the same as the device restore factory settings 6 Sleeping Mode R718F2 is designed to enter sleeping mode for power saving in some situations A While the device is in th...

Страница 7: ...sture and various liquids or moisture may contain minerals that can corrode electronic circuits In case the device is wet please dry it completely Do not use or store in dusty or dirty areas This can...

Отзывы: