2. Appearance

 

 

 

 

 

3. Main Features   

 

Adopt SX1276 wireless communication module 

 

2 x 3.6V ER14505 AA lithium batteries 

 

Trigger the vibration sensor, the device will send trigger information 

 

The base is equipped with a magnet that can be attached to the magnetic substance 

 

IP Ratings: Main part- IP65/IP67 (Optional), Sensor-/IP67 

 

Compatible with LoRaWAN 

TM

 Class A         

 

Frequency hopping spread spectrum technology         

 

Configuration parameters can be configured through third-party software platforms 

 

Data can be read and alerts can be set via SMS text and email (Optional)   

 

Applicable to third-party platforms: Actility / ThingPark, TTN, MyDevices / Cayenne         

 

Low power consumption and long battery life   

 

Note:   

Battery life is determined by the sensor reporting frequency and other variables . Please refer to 

http://www.netvox.com.tw/electric/electric_calc.html   

On this website, users can find various types of battery life time in different configurations.   

Indicator 

Function Key 

Vibration Sensor 

Содержание R718DA

Страница 1: ...Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other p...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...tance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low...

Страница 4: ...ectrum technology Configuration parameters can be configured through third party software platforms Data can be read and alerts can be set via SMS text and email Optional Applicable to third party pla...

Страница 5: ...tor stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network to join The green indicator stays on for 5 seconds succ...

Страница 6: ...Trigger When the device senses vibration and the ball is shaken an alarm message will be reported The shaking alarm bit is 1 The static and non shaking alarm bit is 0 Restore Function There are two wa...

Страница 7: ...00 Configuration failure 2 Read device configuration parameters Downlink 021A000000000000000000 Response 821A003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoad...

Страница 8: ...stops vibrating Downlink 031A010000000000000000 0x01_DO report when sensor restore Response 831A000000000000000000 Configuration success 831A010000000000000000 Configuration failure 2 Read restore fun...

Страница 9: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 10: ...r it is vibrating here take the mousetrap as a picture as shown below 3 The figure shows the vibration sensor R718DA applied to the scene of the mousetrap in the restaurant It can also be applied to t...

Страница 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: