background image

 

 

12 

Note: 

Please do not disassemble the device unless it is required to replace the batteries.   

Do not touch the waterproof gasket, LED indicator light, function keys when replacing the batteries. Please use suitable 

screwdriver to tighten the screws (if using an electric screwdriver, it is recommended to set the torque as 4kgf) to ensure the device 

is impermeable. 

7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages 

including low self-discharge rate and high energy density.      

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode 

and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride layer prevents 

rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation may also lead to 

voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more than 

one month from the date of battery production, all the batteries should be activated. 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω 

5 minutes 

20mA 

RAMWAY 

67 Ω 

8 minutes 

50mA 

EVE 

67 Ω 

8 minutes 

50mA 

SAFT 

67 Ω 

8 minutes 

50mA 

Note:   

If you buy batteries from other than the above four manufacturers, then the battery activation time, activation current, and required 

load resistance shall be mainly subject to the announcement of each manufacturer. 

Содержание R718A

Страница 1: ...User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall...

Страница 2: ...ReportDataCmd 5 5 2 Example of Report Configuration 6 5 3 Example of GlobalCalibrateCmd 8 5 4 Example for MinTime MaxTime logic 9 6 Installation 10 7 Information about Battery Passivation 12 7 1 To de...

Страница 3: ...er communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automat...

Страница 4: ...ers can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility ThingPark TTN MyDevices Ca...

Страница 5: ...k Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the dev...

Страница 6: ...rent Change Reportable Change Any number between 1 65535 Any number between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval The device will immediately send a version packet repor...

Страница 7: ...link 010B019FFF391A9E000000 1st byte 01 Version 2nd byte 0B DeviceType 0x01 R718A 3rd byte 01 ReportType 4th byte 9F Battery 3 1V 1F Hex 31 Dec 31x0 1v 3 1v Low battery 5th 6th byte FF39 Temperature 1...

Страница 8: ...640064 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Config ReportReq R718A 0x01 0x0B MinTime 2bytes Unit s MaxTime 2bytesUnit s Battery Change 1byte Unit 0 1v Temperatu...

Страница 9: ...x00 ClearGlobal CalibrateRsp 0x83 Status 1Byte 0x00_success Reserved 9Bytes Fixed 0x00 Sensor type 0x01_Temperature Sensor 0x02_Humidity Sensor 1 Assume that the reported original value of temperature...

Страница 10: ...last data reported If the data variation is greater than the ReportableChange value the device reports according to MinTime interval If the data variation is not greater than the last data reported th...

Страница 11: ...l shielded box or in an environment with other electrical equipment around it to avoid affecting the wireless transmission of the device The figure shows the scene where the temperature and humidity s...

Страница 12: ...ep 1 Unscrew the four corners of the device with a screwdriver as shown in the red circle below Step 2 Put the batteries into the battery bay of the device and note the positive and negative poles of...

Страница 13: ...into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from reliable vendors and it is suggested that if the storage period is more th...

Страница 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: