Data report configuration and sending period are as following: 

 

 

Min Interval 

(Unit:second) 

Max Interval 

(Unit:second) 

Reportable Change 

Current Change≥ 

Reportable Change 

Current Change

Reportable Change 

Any number between 

1~65535 

Any number between 

1~65535 

Can not be 0. 

Report 

per Min Interval 

Report 

per Max Interval 

    The device will immediately send a version packet report and the attribute report data 

   

The device sends data in the default configuration before any configuration is done. 

    Default setting: 

  MaxTime: Max Interval = 60 min = 3600s 

  MinTime: Min Interval = 60 min = 3600s 

 

Battery

 

Voltage

 

Change

 =

 0x01 (0.1V) 

  Threshold = 0x0003 (Threshold range: 0x0003-0x00FF; 0x0003 is the most sensitive.) 

  Deactivetime = 0x05 (Deactive time range: 0x01-0xFF) 

 

Threshold: 

Threshold = Critical value ÷ 9.8 ÷ 0.0625 

*The gravitational acceleration at standard atmospheric pressure is 9.8 m/s

2

 

*The scale factor of the threshold is 62.5 mg 

 

R313FC vibration alarm: 

The device detects sudden movement or vibration, and the quiescent state changes. The device waits for a certain period of 

time (DeactiveTime) to enter the quiescent state and calculate the duration, sends a report of duration of vibrations, and 

restarts the calculation for the next detection. If the vibration continues to occur within (DeactiveTime), the duration will be 

continuously calculated till it enters the quiescent state. 

 

Note: 

The device report interval will be programmed based on the default firmware which may vary. 

The interval between two reports must be the minimum time. 

Please refer Netvox 

LoRaWAN Application Command document

 and 

Netvox Lora Command Resolver

 

http://loraresolver.netvoxcloud.com:8888/page/index

 to resolve uplink data. 

Содержание R313FC

Страница 1: ...This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Relative Devices 10 8 Important Maintenance Instruction 10 ...

Страница 3: ...ation methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so on LoR...

Страница 4: ...ass A Frequency hopping spread spectrum technology Configuration parameters can be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Indicator Function Key ...

Страница 5: ...oin The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information on the gateway or consult your platform...

Страница 6: ...0xFF Threshold Threshold Critical value 9 8 0 0625 The gravitational acceleration at standard atmospheric pressure is 9 8 m s2 The scale factor of the threshold is 62 5 mg R313FC vibration alarm The device detects sudden movement or vibration and the quiescent state changes The device waits for a certain period of time DeactiveTime to enter the quiescent state and calculate the duration sends a re...

Страница 7: ...ved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 SetR313F TypeReq 0x03 R313FType 1Byte 0x01_R313FA 0x02_R313FB 0x03_R313FC Reserved 8Bytes Fixed 0x00 SetR313F TypeRsp 0x83 Status 0x00_success Reserved 8Bytes Fixed 0x00 GetR313F TypeReq 0x04 Reserved 9Bytes Fixed 0x00 GetR313F TypeRsp 0x84 R313FType ...

Страница 8: ...000000000 The device returns 8451020000000000000000 current device type R313FB 5 Configure the Threshold to 10 Deactive Time to 6s Downlink 0551000A06000000000000 The device returns 8551000000000000000000 configuration succeeded 8551010000000000000000 configuration failed 6 Read the current device type Downlink 0651000000000000000000 The device returns 8651000A06000000000000 current device type R3...

Страница 9: ...ed the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pushed or MaxTime interval another cycle of MinTime MaxTime calculation is started Wakes up and c...

Страница 10: ... transmission of the device 2 When the device detects a sudden movement or vibration of the object or electrical machinery Wait for a certain period of time DeactiveTime default 5 seconds can be modified to enter the quiescent state and it sends a report of duration of vibrations and restarts the calculation for the next detection the timer data will clear Note If the vibration continues to occur ...

Страница 11: ...when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do not apply the device with paint Smudges might block in the device and affect the operati...

Отзывы: