4.Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a flat blade screwdriver to open);   

Insert two sections of 3V CR2450 button batteries and close the battery cover.) 

Turn on   

Press any function key till green and red indicator flashes once. 

Turn off 

(Restore to original setting) 

Press simultaneously and hold two function keys for 5 seconds, and then the green indicator will 

flash continuously. After release function keys, the green indicator flashes 20 times and the device 

will turn off automatically. 

Power off 

Remove Batteries 

Note: 

1. Remove and insert the battery; the device memorizes previous on/off state by default. 

2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor     

inductance and other energy storage components. 

3. Press any function key and insert batteries at the same time; it will enter engineer testing mode. 

Network Joining

 

 

Never join the network 

Turn on the device to search the network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

(Not in the original setting) 

Turn on the device to search the previous network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network 

Suggest checking device verification on gateway or consulting your platform server provider if the 

device fails to join the network. 

Function Key 

 

Press and hold for 5 seconds 

Restore to the original setting / Turn off 

The green indicator flashes 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: the green indicator flashes once and sends a report 

The device is not in the network: the green indicator remains off 

  

Sleeping Mode

 

The device is turned on and 

join in the network 

Sleeping period: Min Interval. 

When the reportchange exceeds the default or the state of the device changes: send a data report 

according to Min Interval. 

 

Содержание R313CB

Страница 1: ...Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ...n 2 2 Appearance 3 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 5 1 Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 7 5 3 Example for MinTime MaxTime logic 8 6 Installation 10 7 Important Maintenance Instruction 11 ...

Страница 3: ... the state is normal When the glass is broken R313CB will send an alarm message to the gateway and then the data which is sent after breakage is based on the current state If it is open the data is an alarm state If it is closed the data is a normal state LoRa Wireless Technology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other co...

Страница 4: ... via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption supports longer battery life Note Battery life is determined by sensor reporting frequency and other variables Please refer to web http www netvox com tw electric electric_calc html In this website users can find battery lifetime for various models at different co...

Страница 5: ...mode Network Joining Never join the network Turn on the device to search the network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Not in the original setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the netwo...

Страница 6: ... in the open state the report status will be 1 The report status will be 0 only when both the main body and the external sensor are closed Triggering the glass sensor When the glass break sensor detects the state changing the report will be sent immediately The status2 No trigger 0 Trigger 1 Note 1 The cycle of the device sending the data report is according to the default 2 The interval between t...

Страница 7: ... 0x56 0x01 Battery 1Byte unit 0 1V Status1 1Byte 0 off 1 on Status2 1Byte 0 off 1 on Reserved 5Bytes fixed 0x00 Example 1 of Uplink 0156011E01000000000000 1st byte 01 Version 2nd byte 56 DeviceType 0x56 R313CB 3rd byte 01 ReportType 4th byte 1E Battery 3v 1E Hex 30 Dec 30 0 1v 3 0v 5th byte 01 Status1 on 6th byte 00 Status2 off 7th 11th byte 0000000000 Reserved Example 2 of Uplink 0156019700010000...

Страница 8: ...0100000000 device current parameter Description Device Cmd ID Device Type NetvoxPayLoadData Config ReportReq R313CB 0x01 0x56 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1v Reserved 4Bytes Fixed 0x00 Config ReportRsp 0x81 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfig ReportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfig ReportRsp 0x82 MinTime 2bytes Unit s Max...

Страница 9: ...00000000000000 configuration failure 4 Read R313CB device parameter Downlink 1EFF000000000000000000 Device return 9EFF050000000000000000 device current parameter 5 3 Example for MinTime MaxTime logic Example 1 based on MinTime 1 Hour MaxTime 1 Hour Reportable Change i e BatteryVoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report accordi...

Страница 10: ...ot recommend setting the MinTime Interval value too low If the MinTime Interval is too low the device will wake up frequently and the battery will be drained soon 3 When the device sends a report no matter the data changes button is pushed or MaxTime interval comes another cycle of MinTime MaxTime calculation starts Wakes up and collects data 2 8V Does not report Wakes up and collects data 2 8V Do...

Страница 11: ...ws or glass doors 2 If R313CB with the glass sensor detects that the window is opened the magnet is separated from the main body or closed the magnet and the main body are closed the data will be sent immediately 3 If the glass breaking vibration triggers the glass sensor the data will be sent immediately 4 If it detects the battery voltage exceeding the variation value at MinTime the data will be...

Страница 12: ...y batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Treating equipment roughly can destroy internal circuit boards and delicate structures Do not wash with strong chemicals detergents or strong detergents Do not ...

Отзывы: