Sleeping Mode
The device is on and in the
network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report
according to Min Interval.
Low Voltage Warning
Low Voltage
2.4V
5.
Data Report
Report configuration and sending cycle are as follows:
Min Interval
(Unit: second)
Max Interval
(Unit: second)
Reportable Change
Current Change
≥
Reportable Change
Current Change
<
Reportable Change
Any number between
1~65535
Any number between
1~65535
Can not be 0.
Report
per Min Interval
Report
per Max Interval
The device will immediately send a version packet report along with an uplink packet including alarm status
The device sends data in the default configuration before any configuration is done.
Default setting:
Maximum time: Max Interval =1 hour
Minimum time: Min Interval=1 hour (the current voltage value is detected every Min Interval)
Battery Change: 0x01 (0.1V)
Alarm button trigger:
Alarm status: 1
Normal status: 0
Note:
(1)
The actual data sending cycle of the device is subject to the programming configuration before shipment.
(2)
The interval between two reports must be the minimum time
The data report can be decoded by the Netvox LoraWAN Application Command document and