NetterVibration NCB 1 Скачать руководство пользователя страница 4

 

 

  

 

NOTICE 

Operation of the vibrators with silencers is mandatory. 

Silencers reduce the noise level and protect the vibrators from contamination entering. 

  

Technical data 

Permissible operating conditions

 

  

Drive medium 

NCT

 must be operated with clean compressed air or nitrogen according to the 

following specification, according 

ISO 8573-1

  

[ 5   :

 

6   :

 

2 ]

 

Filter ≤ 5 µm 

Humidity, pressure- 
dew point ≤ +10 °C 

Total oil content 
≤ 0,1 mg/m

3

 

NCB and NCR 

 must be operated with clean compressed air or nitrogen accord-

ing to the following specification, according 

ISO 8573-1

  

[ 5   :

 

6   :

 

4 ]

 

Filter ≤ 5 µm 

Humidity, pressure- 
dew point ≤ +10 °C 

Total oil content 
≤ 5 mg/m

3

 

All vibrators can be operated oil-free. A mist lubricator extends the service life of 
the NCB and NCR. 

Ambient 
temperature 

Standard: -20 °C to 120 °C 

HT-versions: 80 °C to 200 °C (with brass grommet and sintered silencer) 

Important:

 Below the specified ambient temperature (< 80 °C) the performance 

of the HT-version is reduced. 

Operating pressure 

2,0 to 6,0 bar 

Max. frequency NCT 

The maximum permissible frequency must not be exceeded. 

 

Further technical data can be found in the brochures of the NCT, NCB and NCR on 

www.

Netter

Vibration

.com

  

Connection data

 

  

Type 

Thread 

Tightening 

torque* [Nm] 

Connection 

thread [inch] 

hose/ 

valve size** 

NCT

 1, 2, 3, 4, 4i / 

NCB

 1, 2 / 

NCR

 3 

M6 

10 

G 1/8 

DN 6 

NCT

 5, 10, 10i, 15, 29, 29i 

NCB

 3,5,10,20 / 

NCR

 10, 20 

M8 

25 

G 1/4 

DN 9 

NCB

 50, 70  

M10 

50 

G 3/8 

DN 12 

NCT

 55, 108, 108i / 

NCR

 57 

M12 

87 

G 3/8 

DN 12 

NCT

 126, 250, 250i / 

NCR

 120 

M16 

210 

G 3/8 

DN 12 

* Screws and nuts of the strength class 8.8 (sliding friction coefficient 0.14)        ** DN = Diameter nominal (inner diameter) 

  

Sound level

 

The sound level is largely determined by the mounting surface (e.g. sheet metal) on which the 
vibrator is mounted. Depending on the type, the sound pressure level with a silencer is 75-
85 dB(A) at 6 bar air pressure, at lower air pressure it is below this. Sheet metal which is not 
silenced increases the sound level. 

  

Содержание NCB 1

Страница 1: ...CB 5 NCB 10 NCB 20 NCB 50 NCB 70 Pneumatic roller vibrators NCR 3 NCR 10 NCR 22 NCR 57 NCR 120 Use and storage Before installing the vibrators read these instructions carefully It is the basis for any...

Страница 2: ...past experience to the best of our knowledge into account No claims can be derived from the information illustrations and descrip tions in these operating instructions The manufacturer does not assum...

Страница 3: ...es and connections after one hour of operation and thereafter regu larly generally monthly Retighten the hose lines if necessary Ensure that the compressed air is disconnected from the supply lines du...

Страница 4: ...low the specified ambient temperature 80 C the performance of the HT version is reduced Operating pressure 2 0 to 6 0 bar Max frequency NCT The maximum permissible frequency must not be exceeded Furth...

Страница 5: ...dium Two mounting slots 6 are provided for fastening NCT A turbine 7 rotates in the housing with eccentrically inserted unbalances Depending on the type a different number of unbalances are pressed in...

Страница 6: ...ibrators with two fastening screws and self locking washers on a clean and flat surface flatness of 0 1 mm NetterVibration recommends placing the vibrators on a reinforcement profile U profile or suit...

Страница 7: ...he safety instructions in chap Safety from page 3 on Please refer to chap Technical data page 4 for permissible operating conditions Set frequency Set the centrifugal force or frequency required with...

Страница 8: ...k hose screw connections and hose connections and retighten if necessary Check hose supply lines for permeability and kinking If necessary clean and re move kinks Check the function of the silencer Re...

Страница 9: ...e silencer Wear pollution Have vibrator checked by NetterVibration Only NCT Significant power loss loud noise from bearings Damage to bearings Have NCT checked by NetterVibration Unusual rise in sound...