Detecting Interferers
34
Locate:
Touch this button to open the
Select Interferer
screen and then begin locating an interferer type.
“Locating an Access Point, Client, or Interferer,” page
Caution
To open the
Details
screen for an interferer event, touch its
row.
The Interferer Event Details Screen
The
Interferer Event Details
screen shows the following
detailed information about the interferer you have selected:
Event Number:
The number of the event as assigned by the
AirCheck G2.
Type:
The type of interfering device detected by AirCheck G2.
Average Power:
The average observed power output in
dBm of the interfering device.
Peak Power:
The highest observed power output in dBm of
the interfering device.
Duty Cycle:
The percentage of time, during the most recent
sample, for which the interferer was detected.
Channels Impacted:
The channel numbers for the channels
affected by the interferer.
Number Channels Impacted:
How many channels are
impacted by the detected interferer.
Refresh:
Touch this icon to clear the current
results and restart the scan.
Touching the
Refresh button will erase all
unsaved test results.
Save:
Touch this button to save a session file
containing the discovery or test results that have
been collected since the AirCheck G2 last