Choosing a Setup Location
Note:
This product is intended for installation in a restricted access
location (dedicated equipment rooms, service closets, and the like)
only.
Leave enough clearance in front of the rack to enable you to open the front door completely
(about 25 inches) and approximately 30 inches of clearance in the back of the rack to allow
for sufficient airflow and ease in servicing.
Preparing for Setup
Read these instructions in their entirety before you begin. Locate the ReadyNAS 4200
shipping carton, remove the rack mounting kit and prepare to work with it.
Installing the System into a Rack
To install the system into a rack:
1.
The rack mounting kit contains two rail assemblies. Each assembly consists of two
sections: an inner fixed chassis rail that secures directly to the ReadyNAS 4200 chassis
and an outer fixed rack rail that secures directly to the rack itself. Extend the rail
assembly by pulling it outward. Press the release tab and separate the inner rail from
the outer assembly.