NESiGate Board/Channel Commands
Display Board Config
This button displays the channel boards that have been previously defined.
Prior to selecting this button, provide the following data on the selection screen:
Board Name
the name of the board to display.
If no name is specified in the Board Name window, then all defined channel boards are displayed.
Channel Define Board and Channel Undefine Board
This button deletes or adds the specified channel board from the configuration.
Prior to selecting this button, provide the following data on the selection screen:
Board Name
a 1-8 character name by which the board will be identified in subse-
quent define and display commands.
For ‘Define Board’ the following additional information is needed:
Channel Type
select either
ESCON/SBCON, or
If the board is a Bus&Tag interface, select DCI,
3.0 MB
, or
4.5 MB
,
depending on the speed of the channel to which the board is connected.
PCI Bus
PCI bus number on which the ESCON board is installed.
PCI Device
PCI device in which the ESCON board is installed.
The PCI Bus and Device numbers are dynamically determined and the channel boards are automatically
defined. The Bus and Device numbers can be viewed by selecting the “Display Board Config” button.