Страница 1: ...NetBurner PK70EX 232 4 Port Serial to Ethernet Server Users Manual Revision 1 0 January 29 2008...

Страница 2: ...6 DEVICE CONNECTION SETTINGS UDP MODE 10 7 SERIAL CONFIGURATION 11 8 TESTING WITH A TELNET CONNECTION 14 9 PASSWORD SETUP SECTION 16 9 1 RESETTING A PASSWORD 16 10 DIAGNOSTICS SECTION 17 11 SPECIFICA...

Страница 3: ...b page configuration PK70 Front The PK70 has 6 connectors on the front panel One 10 100 Ethernet Port Two 7 24 VDC Power Connectors One SD MMC Card Slot One Serial Console Port RS 232 UART 0 PK70 Rear...

Страница 4: ...f your PK70 If your PK70 device does not appear in the list box verify the power speed and link LEDs are illuminated and click the Search Again button If you are still unable to see your PK70 remove p...

Страница 5: ...erational Configuration Once the network parameters have been configured you can use the web server interface to modify the settings of your PK70 To access the web page on your PK70 click on the Launc...

Страница 6: ...ces If DHCP from the Address Mode drop down menu is selected the PK70 will obtain its IP Address information automatically including the Subnet Mask Gateway and DNS Server if applicable This is the fa...

Страница 7: ...4 Device Connection Settings TCP Mode This is the bottom section of the first page that you will see when your web browser opens...

Страница 8: ...actory Defaults will restore the factory values Next click on the Advanced Serial Settings link to enter your serial notification information Remember if you are only using one port you can ignore the...

Страница 9: ...nter it in this section Remember to check the appropriate box and click the Submit New Settings button to save your settings The message formatting codes are listed below When finished viewing message...

Страница 10: ...tion You will see System is set to UDP mode after you click the Switch to UDP mode link When you are finished with this section click the appropriate button at the bottom Submit New Port X Values will...

Страница 11: ...her port s section Select the appropriate Port Operating Mode from the drop down menu Select the appropriate data Baud Rate from the drop down menu Your host computer and your attached PK70 must agree...

Страница 12: ...t computer and your PK70 the recommended setting is None Select the appropriate Stop Bits value from the drop down menu The stop bit follows the data and parity bits in serial communication It indicat...

Страница 13: ...Note You must click the Submit New Settings button on the bottom of this page to save your settings Remember if you are only using one port you can ignore the other port s section...

Страница 14: ...s during configuration Procedure 1 Connect your hardware in one of the above configurations 2 Open a command prompt window on your host computer 3 Verify everything is connected correctly by executing...

Страница 15: ...move and reapply power to your PK70 EX The PK70 factory application will boot 5 Run Telnet by typing telnet 10 1 1 79 24 after the prompt and press the Enter key Note This assumes a port number of 24...

Страница 16: ...password 1 Connect the console serial port default is Port 0 on the PK70 to your computer 2 Run the NetBurner MTTTY serial terminal or any serial terminal program on the PC 3 Reboot the PK70 by remov...

Страница 17: ...10 Diagnostics Section Click the Diagnostics link to view the available options To get back to the Networking section click the Back to Ethernet Serial Configuration link...

Страница 18: ...positive and the outer shell is negative Pin Signal Center Positive Shell Negative A 2 pin quick disconnect terminal block Pin Signal 1 Negative 2 Positive 11 3 DB 9 RS232 Serial Connector Ports 1 4...

Страница 19: ...11 4 RJ 45 Connector LED1 on RJ 45 Ethernet speed 10 or 100 LED2 on RJ 45 Link and data activity Pin Signal Pin Signal 1 TX 2 TX 3 RX 4 n c 5 n c 6 RX 7 n c 8 n c 11 5 Mechanical 4 4 x 3 9 x 1 2...

Страница 20: ...e to place on an Intranet Internet If you are going to put the PK70 directly on the Internet then you will need to acquire an IP address If you are on a LAN you will normally choose an IP address from...