Troubleshooting
227
10.3. System does not boot after Configura-
tion Changes
10.3.1. Hardware Changes
If the system does not boot after making changes to hardware or adding new components, verify
that the component installed is compatible with the server.
10.3.2. Software Changes
If you recently installed new software or new device drivers:
• Try booting into Safe Mode and uninstall the new software or driver. If you can now boot normal-
ly, there may be a compatibility issue between the new software or driver and some component
in your system. Contact the soft- ware manufacturer for assistance.
10.3.3. BIOS Changes
Changes to some advanced BIOS settings can cause boot issues. Changes to Advanced BIOS
settings should only be made by experienced users.
If the BIOS Setup Utility is accessible by pressing
F2
during boot, reset the BIOS to factory de-
faults by pressing
F9
. Save and exit the BIOS Setup
If you cannot access the BIOS Setup Utility, clear the CMOS by performing the following steps:
1. Power down the server. Do not unplug the power cord.
2. Open the server chassis
3. Move the CMOS CLEAR jumper from the default operation position, covering pins 1 and 2, to
the reset / clear CMOS, covering pins 2 and 3.
4. Remove AC power.
5. Wait 5 seconds.
6. Move the jumper back to default position, covering pins 1 and 2.
7. Close the server chassis and power up the server.
The CMOS is now cleared and can be reset by going into BIOS setup.
10.3.4. Installation Problems
Perform the following checks if you are troubleshooting an installation problem:
Check all cable and power connections (including all rack cable connections). Unplug the power
cord, and wait one minute. Then reconnect the power cord and try again. If the network is report-
ing an error, see if the server has enough memory and disk space available. Remove all added
Содержание Demos R130 M2
Страница 1: ...Netberg Demos R130 M2 server...
Страница 2: ...Netberg Demos R130 M2 server...
Страница 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Страница 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Страница 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Страница 32: ...19 Chapter 2 Installing hardware...
Страница 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Страница 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Страница 143: ...130 Chapter 6 Server Management Software...
Страница 146: ...Server Management Software 133 6 3 Power System BMC controls system power through GPIO pins and IPMI chassis commands...
Страница 166: ...153 Chapter 7 BMC Recovery This section provides guidelines on BMC recovery process in DOS and Linux systems...
Страница 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Страница 230: ...217 Chapter 9 Rail Kit Assembly...
Страница 233: ...Rail Kit Assembly 220 Figure 9 3 Securing the Inner Rail 5 Repeat steps 1 through 3 for the remaining side...
Страница 236: ...223 Chapter 10 Troubleshooting...