3. Label and then disconnect the controller data cables and any SFP+ or SFP28 transceivers.
To prevent degraded performance, do not twist, fold, pinch, or step on the cables.
4. Loosen the two captive screws on the controller front panel.
5. Slide the SG6000-CN controller forward out of the rack until the mounting rails are fully extended and you
hear the latches on both sides click.
The controller top cover is accessible.
6. Optional: If you are fully removing the controller from the cabinet or rack, follow the instructions for the rail
kit to remove the controller from the rails.
Related information
Remove SG6000-CN controller cover
Reinstall SG6000-CN controller into cabinet or rack
Reinstall the controller into a cabinet or rack when hardware maintenance is complete.
What you’ll need
You have reinstalled the controller cover.
Reinstall SG6000-CN controller cover
Steps
1. Press the blue rail releases both rack rails at the same time and slide the SG6000-CN controller into the
rack until it is fully seated.
When you cannot move the controller any further, pull the blue latches on both sides of the chassis to slide
the controller all the way in.
149