Port
Type
Use
4
Management ports 1 and
2
1-Gb (RJ-45) Ethernet
• Port 1 connects to the
network where you
access SANtricity
System Manager on a
browser.
• Port 2 is reserved for
technical support use.
SG6060: Input/output modules for optional expansion shelves
The expansion shelf contains two input/output modules (IOMs) that connect to the storage controllers or to
other expansion shelves.
Port
Type
Use
1
Drive expansion ports 1-4 12Gb/s SAS
Connect each port to the
storage controllers or
additional expansion shelf
(if any).
Installation and deployment overview
You can install one or more StorageGRID storage appliances when you first deploy
StorageGRID, or you can add appliance Storage Nodes later as part of an expansion.
You might also need to install an appliance Storage Node as part of a recovery operation.
What you’ll need
Your StorageGRID system is using the required version of StorageGRID software.
Appliance
Required StorageGRID version
SG6060 with no expansion shelves
11.1.1 or later
SG6060 with expansion shelves (one or two)
11.3 or later
Note:
If you add expansion shelves after the initial
deployment, you must use version 11.4 or later.