Attention: The MTU value of the network must
match the value configured on the switch port
the node is connected to. Otherwise, network
performance issues or packet loss might occur.
Related tasks
Changing the link configuration of the E5700SG controller
on page 80
You can change the Ethernet link configuration of the E5700SG controller. You can change the
port bond mode, the network bond mode, and the link speed.
Verifying network connections
You should confirm you can access the StorageGRID networks you are using from the appliance.
To validate routing through network gateways, you should test connectivity between the
StorageGRID Appliance Installer and IP addresses on different subnets.
Steps
1. From the StorageGRID Appliance Installer, click Configure Networking > Ping Test.
The Ping Test page appears.
2. From the Network drop-down box, select the network you want to test: Grid, Admin, or
Client.
3. Enter the IPv4 address for a host on that network.
For example, you might want to ping the gateway on the network or the primary Admin Node.
4. Click Test Connectivity.
If the network connection is valid, the "Ping test passed" message appears, with the ping
command output listed.
Hardware Installation and Maintenance Guide for SG5700 Appliances
44
Configuring the hardware