NetApp SOLIDFIRE Скачать руководство пользователя страница 1

 

SOLIDFIRE 

 

SolidFire Storage Node 

‐ 

Getting Started Guide

 

 

1.

 Identifying the Rail Kit Contents

 

2. 

Installing and Removing Tool-Less Rails (Square Hole or Round Hole Racks)

 

Locate the components for installing the 
rail kit assembly: 

 

1 - Two A7 ReadyRails II sliding rail 
assemblies  

 

2- Two hook and loop straps 

 

(

1

) Position the left and right rail end pieces 

labeled FRONT facing inward and orient 
each end piece to seat in the holes on the 
front side of the vertical rack flanges.  
(

2

) Align each end piece in the bottom and 

top holes of the desired U spaces.  
(

3

) Engage the back end of the rail until it 

fully seats on the vertical rack flange and 
the latch clicks into place. Repeat these 
steps to position and seat the front end 
piece on the vertical rack flange.  
(

4

) To remove the rails, pull the latch release 

button on the end piece midpoint and 
unseat each rail. 

 

3.

 Installing and Removing Tooled Rails (Threaded Hole Racks) 

4. 

Installing the System in a Rack 

(

1

) Remove the pins from the front and 

rear mounting brackets using a flat-tipped 
screwdriver.  
(

2

) Pull and rotate the rail latch 

subassemblies to remove them from the 
mounting brackets. 
(

3

) Attach the left and right mounting rails 

to the front vertical rack flanges using two 
pairs of screws. 
(

4

) Slide the left and right back brackets 

forward against the rear vertical rack 
flanges and attach them using two pairs of 
screws. 

 

 

(

1

) Pull the inner slide rails out of the rack 

until they lock into place.  
(

2

) Locate the rear rail standoff on each side 

of the system and lower them into the rear 
J-slots on the slide assemblies.  
(

3

) Rotate the system downward until all the 

rail standoffs are seated in the J-slots.  
(

4

) Push the system inward until the lock 

levers click into place. Press the slide-
release lock buttons on both rails and slide 
the system into the rack. 

 

5.

 Removing the System From the Rack 

6.

 Engaging and Releasing the Slam Latch 

(

1

) Locate the lock levers on the sides of 

the inner rails. 
(

2

) Unlock each lever by rotating it up to its 

release position.   
(

3

) Grasp the sides of the system firmly and 

pull it forward until the rail standoffs are at 
the front of the J-slots. Lift the system up 
and away from the rack and place it on a 
level surface. 

 

NOTE:

 

For systems not equipped with slam 

latches, secure the system using screws, as 
described in step 3 of this procedure. 
(

1

) Facing the front, locate the slam latch on 

either side of the system.  
(

2

) The latches engage automatically as the 

system is pushed into the rack and are 
released by pulling up on the latches.  
(

3

) To secure the system for shipment in the 

rack or for other unstable environments, 
locate the hard-mount screw under each 
latch and tighten each screw with a #2 
Phillips screwdriver. 

 

Notes, Cautions and Warnings

 

NOTE

 

indicates important information that helps you make better use of your computer. 

CAUTION

 

indicates potential damage to hardware or loss of data if instructions are not followed. 

 A WARNING indicates a potential for property damage, personal injury or death. 

 

7. 

Operating Specifications

 

Temperature Range 

Operating: 10

C to 35

C  (Note: for SF19210, Operating Temp Range is 10

C to 30

C)   

Shipping and storing:  -40

C to 65

Relative Humidity 

Operating: 10% to 80%, non-condensing 
Shipping and Storing: 5% to 90%, non-condensing 

Maximum Altitude 

Operating: 3,000 m 
Shipping and Storing:10,000 m 

Maximum Vibration 

Operating:0.26 G

rms

 at 5 Hz to 350 Hz for 15 minutes (all operation orientations) 

Shipping and Storing: 1.87 G

rms

 at 10 Hz to 500 Hz for 15 minutes (all 6 sides) 

Maximum Shock 

Operating: One shock pulse in the positive z axis of 31 G for 2.6 ms in all operational orientations 
Shipping and Storing: Six consecutively executed shock pulses in the positive and negative x, y and z axes (one pulse on each side of the system) up 
to 71 G for up to 2 ms. 

What’s In The Box 

Package Contents: 

 

1 – SolidFire storage node 

 

1 – Slide Rail Kit 

 

1 – Getting Started Guide 

 

2 – Power Cables 

 

1 – End User License Agreement 

NOTE:

 Begin installing the rails in the allotted space that is closest to the bottom of the rack enclosure. 

NOTE:

 The illustrations in this document do not represent a specific system. 

NOTE:

 The tooled rail mounting configuration requires eight user-supplied screws: #10-32, #12-24, 

#M5, or #M6. The head diameter of the screws must be less than 10 mm (0.4”). 

 

This is a condensed reference. Read the safety instructions in your Safety, Environmental, 

and Regulatory Information booklet before you begin. 

 Only trained NetApp service technicians are authorized to remove the system cover and 

access any of the components inside the system. Before you begin, review the safety 

instructions that came with the system.

 