If you had previously disabled SSH functionality on the management node, you need to
on the recovered management node. SSH capability that provides
NetApp Support remote support tunnel (RST) session access
is enabled on the
management node by default.
Upgrade a management node to version 12.2 from 11.3 through 11.8
You can perform an in-place upgrade of the management node from version 11.3, 11.5, 11.7, or 11.8 to version
12.2 without needing to provision a new management node virtual machine.
The Element 12.2 management node is an optional upgrade. It is not required for existing
deployments.
What you’ll need
• The management node you are intending to upgrade is version 11.3, 11.5, 11.7, or 11.8 and uses IPv4
networking. The management node version 12.2 does not support IPv6.
To check the version of your management node, log in to your management node and
view the Element version number in the login banner.
• You have updated your management services bundle to the latest version using NetApp Hybrid Cloud
Control (HCC). You can access HCC from the following IP: <code><a
href="https://<ManagementNodeIP>" class="bare">https://<ManagementNodeIP></a>;</code>
• If you are updating your management node to version 12.2, you need management services 2.14.60 or
later to proceed.
• You have configured an additional network adapter (if required) using the instructions for
.
Persistent volumes might require an additional network adapter if eth0 is not able to be
routed to the SVIP. Configure a new network adapter on the iSCSI storage network to
allow the configuration of persistent volumes.
• Storage nodes are running Element 11.3 or later.
Steps
1. Configure the management node VM RAM:
a. Power off the management node VM.
b. Change the RAM of the management node VM from 12GB to 24GB RAM.
c. Power on the management node VM.
2. Log in to the management node virtual machine using SSH or console access.
3. Download the management node ISO for
software from the NetApp Support Site to
the management node virtual machine.
The name of the ISO is similar to
solidfire-fdva-<Element release>-patchX-
XX.X.X.XXXX.iso
4. Check the integrity of the download by running md5sum on the downloaded file and compare the output to
what is available on NetApp Support Site for NetApp HCI or Element software, as in the following example: