Chapter 3: Replacing Disk Shelf Devices
51
Replacing an ESH2/ESH4 module
Installing a module
Installing an
module
To install a module into the disk shelf, complete the following steps.
Attention
Observe the “
Disk shelf cabling requirements
” on page 32 and do not mix
ESH2/ESH4 modules within a shelf.
Step
Action
1
Verify that your system meets the minimum software requirements to
support the disk shelf and module combination. See the System
Configuration Guide at
http://now.netapp.com
for more information.
2
Put on the antistatic wrist strap and grounding leash.
3
Push apart the levers on the CAM mechanism and slide the module
into the slot at the rear of the disk shelf, then push the levers of the
CAM mechanism into place.
Attention
Do not use excessive force when sliding the module into the disk
shelf; you might damage the connector.
4
Reconnect the Fibre Channel cabling.
5
Turn on the power to the disk shelves.
6
Reboot the system.