Monitoring the ESH2 or ESH4 modules
Terminate (Term) switch state:
The following table lists and describes the
terminate switch status.
Note
The information in the following table is not applicable to the ESH2 because it
does not have a terminate switch.
ESH2/ESH4 port state:
The following table lists and describes the
ESH2/ESH4 status responses.
MISSING
ESH2/ESH4 is missing from the specified slot.
XPORT ERROR
Communication with the ESH2/ESH4 is not possible.
Shelf state
Description
OK
Terminate switch is in the Off position. This DS14mk2 FC is
connected to another DS14mk2 FC in the loop.
TERM
Terminate switch is in the On position. This DS14mk2 FC is
the last shelf in the loop.
TERM-ERR
Forced terminate event. The terminate switch is in the On
position even though this DS14mk2 FC is connected to
another DS14mk2 FC in the loop. The output port LED
flashes to indicate this configuration error.
AUTO-TERM
Terminate switch is in the Off position. The output port is no
longer connected to another DS14mk2 FC in the loop, but it
once was. The output port LED flashes to indicate this
configuration error.
Shelf state
Description
OK
Port is functioning normally.
EMPTY
No drive is present in bay.
BYP/TBI
Port failed loop test before insert and was not allowed into
loop.
Shelf state
Description
Содержание DiskShelf14mk2 FC
Страница 12: ...6 Before you begin your installation For DS14mk2 FC ...
Страница 23: ...Chapter 2 Monitoring the Disk Shelf 17 For DS14mk2 FC ...
Страница 36: ...30 Monitoring the Fibre Channel disk For DS14mk4 FC ...
Страница 72: ...66 Hot adding a disk shelf to an existing adapter in your system ...
Страница 90: ...84 Index ...