18
Monitoring the ESH2 or ESH4 modules
For DS14mk4 FC:
Console error
messages for the
modules
The following error messages appear on your system console if an SES element
on the module fails. For information about replacing the module, see “
Error message
Action required
SES electronics
Element 1: component
is from a different
product family
Module A was replaced and the shelf has the
unsupported configuration of ESH2 and ESH4.
This error message occurs during the process of
hot-upgrading.