8
Before you begin your installation
The system uses the enclosure services monitoring method to monitor
environmental conditions of the disk shelf. Enclosure services conditions are
communicated to the system through the ESH2 or ESH4 module.
The following table describes the three stages of enclosure services monitoring.
Stage
Device
What it does...
1
System
Uses a subset of SCSI-3 commands to monitor the
disk shelf for data related to disk presence,
temperature, power supply units, and fan status.
2
System
Sends the commands through its Fibre Channel
interface to drive bays 0 and 1 on the disk shelf.
3
Drive bays 0
and 1
Communicate the request to the ESH2 or ESH4
module and send the data to the system.
ESH2 or ESH4
module
Collects the requested data and sends it to drive
bays 0 and 1.
4
5
6
7
8
9
10
11
12
13
3 2 1 0
0
POPULATE
BAYS 0 & 1
FOR
ENCLOSURE
SERVICES
Label