NetApp AltaVault Cloud Integrated Storage Administration Guide
223
Beta Draft
Replacing system DIMMs
System maintenance AVA-400, AVA-800
8.
Reinstall the controller module in the chassis and connect the power as described in
. In this case, the system begins to boot but stops at the loader prompt.
Note:
All subsequent steps in this procedure are done at the loader prompt.
9.
For initializing the new boot media, you must contact technical support.
Important:
This procedure requires advanced knowledge of AltaVault systems and should not be done without help from technical
support. Contact technical support to assist you in copying the system files and OS version to the boot media and bringing your
system back up to a healthy state, after the boot media replacement procedure.
Replacing system DIMMs
An AltaVault controller has eight 32G DIMMs, also known as system memory. The DIMMs encounter correctable and
uncorrectable errors during the normal operation of the system.
With a uncorrectable memory errors, the system reboots.
With correctable memory errors, the system does not reboot; the errors are recoverable and messages are
recorded in the log.
Removing system DIMMs
System DIMMs are not hot-swappable FRUs. To remove a system DIMM from the AltaVault controller, shut down
the system and remove the controller module from the chassis. Replace the failed DIMM with a replacement DIMM
that is supported on your storage system.
Before you begin
Perform a clean system shutdown using the
reload halt
command.
Power down the system and disconnect power from it. For detailed instructions on performing a clean system
shutdown and disconnection power, see
“Shutting down the AltaVault controller” on page 203
Remove the controller requires assistance from NetApp support.
To remove a system DIMM
1.
If
you
are not already grounded, properly
ground yourself
.
2.
Open the CPU cover in the AltaVault controller to access DIMMs 1, 2, 5, and 6.
Loosen the thumbscrew on the appropriate side panel and remove the side panel to access DIMMs 3, 4, 7, and 8;
left side panel for DIMMs 3 and 4, and right side panel for DIMMs 7 and 8.
Содержание AltaVault AVA400
Страница 2: ...Beta Draft ...
Страница 10: ...Beta Draft Contents ...
Страница 182: ...182 NetApp AltaVault Cloud Integrated Storage Administration Guide Disaster recovery Disaster recovery ...
Страница 246: ...246 NetApp AltaVault Cloud Integrated Storage Administration Guide AltaVault appliance MIB SNMP traps ...
Страница 266: ...266 NetApp AltaVault Cloud Integrated Storage Administration Guide Beta Draft Copyright Information ...
Страница 268: ...268 NetApp AltaVault Cloud Integrated Storage Administration Guide Beta Draft Trademark Information ...
Страница 270: ...270 NetApp AltaVault Cloud Integrated Storage Administration Guide Beta Draft How to Send Your Comments ...