INSTALLATION
Screen Filter
Install add-ons (optional)
•
It is recommended to install a secondary (screen) filter
on the main line, downstream from the media filtration
system.
•
It is recommended to install a manual isolation valve
downstream from the media filtration system for
maintenance purposes.
24.
Flatten the surface of the media.
25.
Make sure that the filling port and its gasket are clear of any remaining gravel particles and close the
filling port.
19.
Close all the openings of the manifold end-caps with the 2” plugs supplied with the control kit.
20
. Connect the filtration system inlet and outlet to the main irrigation line with grooved couplings.
21.
Connect the backwash pipe to the backwash manifold with grooved couplings.
22.
Visually check (with the aid of a flashlight) the inside of all the tanks, through the filling port, for
damaged, missing or unsecured under-drain diffusers (“flutes”). Replace, re-fit, re-connect and re-
secure if necessary.
ATTENTION
Before filling the tanks with media
Fill each tank with water up to a third of its height with a hose through the filling port adding
media, to prevent damage to the under-drain diffusers when pouring the media.
23.
Fill the tanks with media through the filling port. Fill each
tank up to the media level marker on the filter tank.
*Crushed silica sand. Quantity may vary depending on
manufacturer specifications.
Tank diameter
(lbs)
16
200
20
260
24
400
Tank diameter
(inches)
(inches)
Sand quantity*
Sand quantity*
(lbs)
30
590
36
770
48
1485
Single-chamber
Double-chamber
Содержание SANDSTORM
Страница 1: ...INSTALLATION MANUAL SANDSTORM METAL SINGLE DOUBLE CHAMBER MEDIA FILTER ...
Страница 22: ...22 SANDSTORM SINGLE DOUBLE CHAMBER INSTALLATION MANUAL ...
Страница 23: ...SANDSTORM SINGLE DOUBLE CHAMBER INSTALLATION MANUAL 23 ...
Страница 24: ...SSIM V2 01 3 19 NETAFIM USA 5470 E HOME AVE FRESNO CA 93727 CS 888 638 2346 www netafimusa com ...