Netafim ICU Скачать руководство пользователя страница 1

Netafim USA CMT

NETAFIM ICU - INTERNET 
CELLULAR MODEM

Real Port Installation

ICU Connections

Содержание ICU

Страница 1: ...Netafim USA CMT NETAFIM ICU INTERNET CELLULAR MODEM Real Port Installation ICU Connections ...

Страница 2: ...ower Supply CD with Instructions and PC software Important The ICU Modem is ready to use It is pre configured by Netafim USA and includes a Verizon Cellular Data Plan with Static IP Address The account will to be transferred to the customer within 30 days of plan activation For additional information contact your Netafim USA Dealer ...

Страница 3: ...na for Cellular Modem Model Number 00107 004970 6 ft Cable with 9DB female 9 pin plug for NMC Controllers direct communication Model Number 00107 011205 NMC Pro Communication Radio Card RS232 Model Number 74340 009110 NMC Junior Communication RS232 Card Model Number 74340 006600 ...

Страница 4: ...r Modem connected to your NMC Controller will select one of the Com Port numbers not in use and this will be the Virtual Com Port The Virtual Com will be selected on the NMC Net PC software for communication with your remote controller Note To communicate with your remote NMC Controller the PC needs to have Internet service REAL PORT SOFTWARE INSTALLATION ...

Страница 5: ...2 Bytes 64 Bytes 1 Insert the Netafim CD and open the Real Port File 2 If your PC has 32 Bytes run the Setup32 exe file and if your PC has 64 Bytes run the Setup64 exe file REAL PORT SOFTWARE INSTALLATION ...

Страница 6: ...6 REAL PORT SOFTWARE INSTALLATION On Set up Screen select Add a New Device Click Next ...

Страница 7: ... on the ICU modem white label Select a Comm Port that is not in use this port will show up in NMC Net All other information on this screen is allocated by default and should not need any input Click Finish Com 2 Com 2 COMPUTER PORT SET UP ...

Страница 8: ... is only used to verify that the Real Port is set up correctly Skip this or use to troubleshoot On the PC find the Device Manager and Click the Hardware Tab Click the Device Manager CHECKING COM PORT PC ALLOCATION ...

Страница 9: ...anced Open Device Manager on the PC Connections will show the Real Port status Connected means that the Real Port is communicating with the Netafim ICU Cellular Modem This step is only used to verify that the Com Port is set up correctly Skip this or use to troubleshoot CHECKING COM PORT PC ALLOCATION ...

Страница 10: ...m When the external antenna is required it needs to be connected on the Primary Cellular 2 Connect the Netafim Direct Plug to the modem 3 Connect the power supply to the modem and twist turn clockwise The green LED power will light 4 After a few seconds the signal strength LED will light NETAFIM ICU CELLULAR MODEM ...

Страница 11: ... Jumpers are on DIR position upper and middle pin 3 Connect the 3 Wires from the Netafim Direct connector to the lower plug Black to Com White to TX Red to RX 4 Jumpers on DIR NETAFIM ICU CELLULAR MODEM Connections between the ICU Cellular Modem and the NMC Controllers NMC Pro or NMC DC Controller ...

Страница 12: ... Note the Left Right direction on the card 2 Verify that the 4 Jumpers are on DIR position lower and middle pin 3 Connect the 3 Wires from the Netafim Direct connector Black to Com White to TX Red to RX NETAFIM ICU CELLULAR MODEM Connections between the ICU Cellular Modem and the NMC Controllers ...

Страница 13: ...un the NMCNet PC Software to communicate and interact with the NMC Controller See the NMCNet User Manual for instructions on NMCNet installation For Technical assistance please call your local Netafim Dealer NMCNET PC SOFTWARE ...

Отзывы: