10
GyroNet
TM
Turbo
USER MANUAL
TECHNICAL DATA
Flow
rate*
(l/h)
Nozzle
size
(mm)
Color
code
Working
pressure
(bar)
Trajectory (m)
Height Distance
200
1.89
Yellow
2.0
0.65
3.14
2.5
0.71
3.25
3.0
0.77
3.25
250
2.14
Purple
2.0
0.80
3.31
2.5
0.88
3.50
3.0
0.90
3.55
300
2.31
Green
2.0
0.83
3.27
2.5
0.92
3.50
3.0
2.95
3.54
400
2.67
Blue
2.0
0.87
3.37
2.5
0.92
3.56
3.0
0.98
3.65
500
3.00 Brown
2.0
0.92
3.58
2.5
1.02
3.72
3.0
1.02
3.90
Riser
tube
length
(m)
Flow rate* (l/h)
200
250
300
400
500
Head loss (bar)
1.2
0.017
0.025
0.034
0.057
0.084
Riser tube: OD 12.0 mm
, ID 9.0 mm
Riser tube: ½"
, ID 15.0 mm
Riser
tube
length
(m)
Flow rate* (l/h)
200
250
300
400
500
Head loss (bar)
0.4
0.000
0.001
0.001
0.002
0.002
0.8
0.001
0.001
0.002
0.003
0.005
1.2
0.001
0.002
0.003
0.005
0.007
Riser tube: ¾"
, ID 20.5 mm
Riser
tube
length
(m)
Flow rate* (l/h)
200
250
300
400
500
Head loss (bar)
0.4
0.000
0.000
0.000
0.000
0.001
0.8
0.000
0.000
0.000
0.001
0.001
1.2
0.000
0.000
0.001
0.001
0.002
Sprinkler water trajectory
A
B
A. Distance
- Distance of max. trajectory height from sprinkler nozzle.
B. height
- Elevation of max. trajectory height above ground.
Trajectory height above sprinkler nozzle
The maximum trajectory height above the sprinkler nozzle is relevant in the following cases:
•
When sprinklers are used under the canopy to prevent wetting the foliage.
•
When sprinklers are used in a net-house or inside a roofed structure such as a glasshouse, to prevent
wetting the net or the ceiling.
Head loss in riser tube
*Nominal flow rate at 2.5 bar working pressure.
Water trajectory angle: 30 degrees