background image

Thank you for purchasing a AlphaDisc™ filter.
For filter operation and maintenance, please follow the instructions in this manual.
For additional information about the AlphaDisc™ filter, please scan the QR code or visit our 

website

.

The AlphaDisc™ series of automatic self-cleaning filters, was designed for water filtration only, and 
must be operated within the pressure limitation specifications.

 INTRODUCTION

QUICK GUIDE

 

AlphaDisc

™ 

Single

AlphaDisc

™ 

Dual

AlphaDisc

™ 

Trio

Содержание AlphaDisc 3

Страница 1: ...r additional information about the AlphaDisc filter please scan the QR code or visit our website The AlphaDisc series of automatic self cleaning filters was designed for water filtration only and must be operated within the pressure limitation specifications INTRODUCTION QUICK GUIDE AlphaDisc Single AlphaDisc Dual AlphaDisc Trio ...

Страница 2: ...ited and not allowed to reproduce copy duplicate manufacture supply sell hire distribute or adapt all or any part of this publication including any packaging Netafim are trademarks of Netafim Ltd registered in the U S and other countries We endeavor to provide accurate quality and detailed information However we cannot accept liability for your reliance on the provided information and you are advi...

Страница 3: ... AlphaDisc Filters quick user guide V1 0 3 1 The AlphaDisc Series 2 The AlphaDisc XL Series AlphaDisc 3 Inline Angle Angle Inline Online Reverse angle Reverse angle Online AlphaDisc XL 4 ...

Страница 4: ...isc Filters quick user guide V1 0 4 AlphaDisc Dual Series 4 AlphaDisc Dual 6 AlphaDisc XL Dual 8 AlphaDisc XL Trio 6 AlphaDisc Trio AlphaDisc Trio Series 3 The AlphaDisc Dual Series 4 The AlphaDisc Trio Series ...

Страница 5: ... AlphaDisc Filters quick user guide V1 0 5 5 Dimensional Drawings AlphaDisc Single 3 In line AlphaDisc Single 3 On line AlphaDisc Single 3 Angle AlphaDisc Single 3 Reverse Angle ...

Страница 6: ... AlphaDisc Filters quick user guide V1 0 6 AlphaDisc Single XL 3 In line AlphaDisc Single XL 3 On line AlphaDisc Single XL 3 Angle AlphaDisc Single XL 3 Reverse Angle ...

Страница 7: ... AlphaDisc Filters quick user guide V1 0 7 AlphaDisc Single XL 4 In line AlphaDisc Single XL 4 On line AlphaDisc Single XL 4 Angle AlphaDisc Single XL 4 Reverse Angle ...

Страница 8: ... AlphaDisc Filters quick user guide V1 0 8 AlphaDisc Dual 4 AlphaDisc Dual XL 6 ...

Страница 9: ... AlphaDisc Filters quick user guide V1 0 9 AlphaDisc Trio 6 AlphaDisc Trio XL 8 ...

Страница 10: ...B 156 KG 344 LB CONSULT NETAFIM FOR OPTIMUM FLOW DEPENDING ON FILTRATION DEGREE AND WATER QUALITY CONTROL POWER SUPPLY 4 X AA TYPE 1 5V BATTERIES EXTERNAL 7 14V DC SOLENOID OPERATION DATA 9 12V DC LATCHING SOLENOID DP SWITCH INTEGRAL SENSORS CONTROL POWER SUPPLY 4 X D TYPE 1 5V BATTERIES EXTERNAL 7 14 VDC SOLENOID OPERATION DATA 9 12 V DC LATCHING SOLENOID DP SWITCH INTEGRAL SENSORS EXHAUST VALVE ...

Страница 11: ... PP PA PP PA PP FLOW RATE 130 MICRON SINGLE 3 DUAL 4 TRIO 6 M2 H GPM M2 H GPM M2 H GPM WATER QUALITY GOOD 50 220 100 440 150 660 AVERAGE 40 176 80 352 120 528 POOR 35 154 70 308 105 462 VERY POOR 25 110 50 220 75 330 CCM CLOGGING WATER QUALITY GOOD 15 AVERAGE 5 15 POOR 2 5 5 VERY POOR 1 5 2 5 Availability of disc type and micron size ...

Страница 12: ...HT EMPTY 57 KG 126 LB 58 KG 129 LB 127 KG 279 LB 182 KG 401 LB CONSULT NETAFIM FOR OPTIMUM FLOW DEPENDING ON FILTRATION DEGREE AND WATER QUALITY CONTROL POWER SUPPLY 4 X AA TYPE 1 5V BATTERIES EXTERNAL 7 14V DC SOLENOID OPERATION DATA 9 12 V DC LATCHING SOLENOID DP SWITCH INTEGRAL SENSORS CONTROL POWER SUPPLY 4 X D TYPE 1 5V BATTERIES EXTERNAL 7 14 VDC SOLENOID OPERATION DATA 9 12 V DC LATCHING SO...

Страница 13: ...LE 3 XL DUAL 4 TRIO XL 6 TRIO XL 8 M2 H GPM M2 H GPM M2 H GPM M2 H GPM WATER QUALITY GOOD 80 352 110 484 220 968 330 1 452 AVERAGE 60 264 90 396 180 792 270 1 188 POOR 55 242 80 352 160 704 240 1 056 VERY POOR 50 220 70 308 140 616 210 924 CCM CLOGGING WATER QUALITY GOOD 15 AVERAGE 5 15 POOR 2 5 5 VERY POOR 1 5 2 5 Availability of disc type and micron size ...

Страница 14: ... AlphaDisc Filters quick user guide V1 0 14 8 AlphaDisc Filtration Process 9 AlphaDisc Backwash Process ...

Страница 15: ... 12 lockers rotate each one clockwise using your fingers in the designated grooves 2 Open the top of the carton box and remove the filter Note Inside the carton box you will find Multifunction tool Installation operation and maintenance instructions 2 support legs Control tubes ...

Страница 16: ...he product from the supporting bridges 4 Prior to installation cut the plastic strips and lift the supporting bridge to release the product Repeat this procedure on the other side to release the product completely Note In the On line configuration the command filter is disconnected during shipment ...

Страница 17: ... AlphaDisc Filters quick user guide V1 0 17 5 Install the command filter ...

Страница 18: ...ide V1 0 18 11 Unpacking Battery Filter 1 Remove the plastic shrink wrap that covers the filter 2 Place the AlphaDisc on a flat surface in its final installation position 3 Disconnect the three screws and separate the horizontal beams ...

Страница 19: ... AlphaDisc Filters quick user guide V1 0 19 4 Disconnect the vertical beams by releasing the bottom screws on each corner ...

Страница 20: ... AlphaDisc Filters quick user guide V1 0 20 5 Connect the command filter Note The command filter is disconnected during shipment ...

Страница 21: ... AlphaDisc Filters quick user guide V1 0 21 6 Remove the air release cap Note The air release valve is removed during shipment and needs to be reinstalled after the AlphaDisc is in its final position ...

Страница 22: ... AlphaDisc Filters quick user guide V1 0 22 7 Install the air release valve ...

Страница 23: ...ach AlphaDisc unit Below is a summary of its various usage options FINGER FILTER SERVICING UNIVERSAL CONNECTION NUT COMMAND FILTER COVER NUT SYSTEM CLAMP JOINING BOLTS M8 BOLTS EQ 13MM 1 2 SPANNER MAIN CLAMP JOINING BOLTS M10 BOLTS EQ 17MM 11 16 SPANNER 2 SPINE COVER TIGHTENING NUT 4 SPINE COVER TIGHTENING NUT ...

Страница 24: ...he inlet and outlet ports according to the installation configurations described below keep the service clearance from both sides as shown Note Ensure that the direction of the flow is aligned with the arrows marked on the filter housing It is recommended to install inlet and outlet isolation valves For added support the legs included in the carton box may be installed on the single unit see the s...

Страница 25: ... AlphaDisc Filters quick user guide V1 0 25 SINGLE ON LINE BATTERY ...

Страница 26: ...ion after maintenance follow these steps 1 Retighten the system s universal nuts 2 Open the outlet valve 3 Open the inlet valve slowly 4 Make sure there are no leaks in the filter 5 Initiate 1 flushing cycle by manually operating the controller 6 Examine the filter again for any leaks SINGLE BATTERY ...

Страница 27: ...Note Check that the back pressure in the drain manifold during flushing does not exceed 0 5 bar 7 5 psi If it does disconnect the accelerator s drain tubes to ensure optimal performance See instructions below The filter is supplied with disconnected drain tubes ...

Страница 28: ...miad Water Systems Ltd APPROVED DRAWN NOVA PLUS ADI X 2 SOLENOIDS PNID SHEET 1 OF 1 NOVA PLUS ADI X 2 SOLENOIDS PNID רביעי יום 22 יולי 2020 16 20 06 Zali Zali 21 07 2020 shai 21 07 2020 21 07 2020 D E F C File Location C 3DEXPERIENCE AMIAD Solidworks K Kit Assy 11 117100 8 7 6 5 4 3 2 1 F D A C E B 8 6 7 5 2 3 1 4 A B DRY WEIGHT WET WEIGHT KG KG CHECKED B DRW REV UNLESS OTHERWISE SPECIFIED DIMENSI...

Страница 29: ...ALVES FAIL TO REVERSE FLOW HYDRAULIC RESISTANCE IN THE DRAIN PIPE DISCONNECT THE DRAINPIPE CHECK THE LENGTH DIAMETER AND THE PIPE INCLINE MECHANICAL RESTRICTION OF THE IN TERNAL VALVE S ACTUATOR REMOVE THE CYLINDER BOOSTER COVER PULL OUT THE INTERNAL ACTUATOR REPAIR OR REPLACE IN CASE ALL THE ABOVE DO NOT APPLY CONSULT YOUR LOCAL DISTRIBUTOR SYMPTOM POSSIBLE CAUSES REQUIRED ACTIONS STRONG LEAKAGE ...

Страница 30: ...LEANING OF THE DISCS CLOSE THE INLET VALVE REMOVE THE DISCS ELEMENT AND MANUALLY CLEAN THE DISCS BY USING PRESSURIZED WA TER JETS DP IS NORMAL BUT THE FILTER IS STILL BACKWASHING NONSTOP INCORRECT FLUSHING PROGRAM CHECK AND SET THE RECOMMENDED FLUSHING PROGRAM THE BACKWASH VALVES FAILED TO COM PLETE A REVERSE FLOW FROM FILTERING TO FLUSHING MODE CHECK THE BACKWASH VALVES PERFOR MANCE REPAIR OR REP...

Страница 31: ...r unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events II Fault abuse or negligence of the Buyer III Intake water not meeting the agreed standards as set forth in a written document approved by Netafim or improper storage IV Improper or unauthorized use of the product or related parts by the Buyer including Buyer s failur...