3
Brütsch/Rüegger Werkzeuge AG, Heinrich Stutz-Strasse 20, Postfach, CH-8902 Urdorf, Tel. +41 44 736 63 63, Fax +41 44 736 63 00, www.neriox.tools, [email protected]
Legend
1. Measuring clamp
2. Carbide measuring surfaces
3. Measuring spindle
4. Locking device
5. Scale
6. Ratchet
7. Heat protection plate
8. ON/OFF - SET button
9. ABS/INC - UNIT button
10. LCD display
11. Battery compartment (rear side)
Specification
Measuring range:
0…25 mm
Resolution:
0.001 mm
Spindle pitch:
2 mm / revolution
Measuring force:
5…10 N
Operating temperature:
0…40°C
Power:
Battery SR44 / 1.55V
Protection class:
IP65
Properties
ON/OFF:
Switch display on/off
SET:
Set pre-selection value (zeros)
ABS/INC:
Toggle measuring mode
UNIT:
Toggle mm/inch
Auto-Power OFF:
Automatic shutdown
Operation
Switch on/off:
Short press of ON/OFF button
Set pre-selection value (zeros): Long press of SET button
Toggle measuring mode:
Short press of ABS/INC button
Toggle measuring unit:
Long press of UNIT button
DIGITAL MICROMETER QUICK
Operating instructions
Safety instructions
• Clean measuring surfaces before use
• Use the micrometer only at the permissible operating temperature
• Protect the micrometer from mechanical damage
• The electronics must not be exposed to a strong magnetic field
• The electronics must not be opened
• If the battery icon flashes in the display - change the battery
• Dispose of battery and micrometer properly
Instructions for care
A soft cloth can be used for cleaning the surfaces.
Do not use petrol, acetone or isopropanol for cleaning under any circumstances.
Remove the battery if the instrument is not going to be used for an extended period.
MAN_BR
W
_div
. March_20_art. BR
W
115155
Repair
If the instrument is defective, please contact our
service centre → [email protected]
1
7
2
3
4
8 9
5
6
115155
11
10