Neptune WTA Series Скачать руководство пользователя страница 1

WTA  Series  Ultraviolet  Water  Disinfection  System

 

 

Installation,  Operation  and  Maintenance  Manual

 

KEEP  THIS  MANUAL  ON  HAND

 

IMPORTANT:    

Anyone  responsible  for  the  installa on,  maintenance  or  opera on  of  this  equipment  must  have  a  

thorough  understanding  of  the  instruc ons  and  safety  requirements  before  a emp ng  to  install  this  system.

 

 

 

 

 

 

Sold  By:

 

 

Models  WTA

-

4,  WTA

-

7,  WTA

-

10  &  WTA

-

15

 

Содержание WTA Series

Страница 1: ...nce Manual KEEP THIS MANUAL ON HAND IMPORTANT Anyone responsible for the installa on maintenance or opera on of this equipment must have a thorough understanding of the instruc ons and safety requirem...

Страница 2: ...Selection 8 e Environmental Issues Relating to UV Lamps 8 5 Installation Instructions 9 a Quartz Sleeve Installation 10 b Lamp Installation 12 c Plumbing System Sanitization Procedure 13 6 Operation...

Страница 3: ...3...

Страница 4: ...worn to protect from UV light as well as debris HAND PROTECTION This symbol signifies that hand protection must be worn to protect the lamps from skin oils as well as protect the operator from UV ligh...

Страница 5: ...e wavelength for this process When many pathogens are exposed to UV light their cells become damaged and this damage inhibits reproduction The UV light produced by a special UV lamp damages the cell s...

Страница 6: ...lug if it is malfunctioning or if it is dropped or damaged in any way x The power cord of disinfection system is equipped with a 3 prong grounding plug that mates with a standard 3 prong grounded wall...

Страница 7: ...ges are dependent upon the quality and clarity of incoming water Impurities in water can interfere with UV intensity and cause dosage to fall to unsafe levels Have your water tested to determine it me...

Страница 8: ...le for water damage x Vibration of ultraviolet equipment will damage lamps and lead to premature system failure Choose a location for your WTA system that is isolated from vibration Potential vibratio...

Страница 9: ...LECTRICAL SHOCK Check for hidden electrical wiring before drilling holes INSTALLATION ORIENTATION Water flow must be from the bottom to the top of the unit for a vertical installation Inlet and outlet...

Страница 10: ...d by the quality of the water passing through the system Use cloth gloves to handle quartz sleeves and UV lamps to avoid putting fingerprints on the sleeves and lamps After the ultraviolet unit has be...

Страница 11: ...of the quartz sleeve After you have tightened the gland nuts and all other plumbing connections open the outlet valve Slowly open the inlet valve and flush out all remaining air Then close the outlet...

Страница 12: ...prints get on the lamp wipe it with a clean cloth and denatured alcohol Take care when removing the ultraviolet lamp from the packing carton Slowly and carefully slide the lamp into the quartz sleeve...

Страница 13: ...f chlorine depends upon the diameter and depth of your well As a general rule of thumb use gallon to treat an 8 diameter 80 deep well and one gallon for anything larger Pour household bleach into your...

Страница 14: ...diately replace any failed lamp The ballast located midway on the power cord has built in monitoring functions to indicate lamp operation The LED will glow green when the lamp is operational and red w...

Страница 15: ...rom the original levels at the end of one year your UV system is designed to provide rated dosage at the end of lamp life to provide safe and effective disinfection When a new lamp is installed it is...

Страница 16: ...essel Unscrew the strain relief securing the lamp connector from the compression nut and slide the lamp out about 2 from the compression nut Remove the lamp connector from the lamp and carefully remov...

Страница 17: ...1 WTA RB WTA RB 2 Compression Nut WTA CN WTA CN WTA CN WTA CN 3 Lamp 05 0340 1 05 0294 1 05 0343 1 05 0319 1 4 Quartz Sleeve WTA Q4 WTA Q7 WTA Q10 WTA Q15 5 O Ring EPDM 42213 42213 42213 42213 6 Chamb...

Страница 18: ...0V 50 60Hz WTA 15 31 5 2 5 4 3 36 8 1 MPT 100 240V 50 60Hz Table 4 Be sure to leave unobstructed clearance on one end of the UV unit for removal of lamp and quartz sleeve Recommended clearance is leng...

Страница 19: ...ve ac on Water supply cannot exceed maximum concentra on levels as shown in Table 1 in Pre Installa on Instruc ons x Verify ow rate vs disinfec on levels as shown in Technical Speci ca ons Table 3 Lam...

Страница 20: ...od on replacement lamps will be veri ed using date codes and or purchase receipts Water Treatment Accessories will advise whether the defec ve item needs to be returned for failure analysis None of th...

Страница 21: ...21...

Страница 22: ...maintenance or necessary service on your system record the dates in the maintenance log The maintenance section of the IOM Manual provides instructions for servicing and maintenance procedures Replace...

Страница 23: ...NOTES...

Страница 24: ......

Отзывы: