background image

December 2004                                                        10                                                               

16025861

©2004 Maytag Services

!

WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing,
unless testing requires it.

Troubleshooting

Diag.

Code

Description

Trigger

Action to be Taken

08

Water sensor level
fault

The low water level is

not satisfied before the
high water level

contacts are opened

in the pressure switch

Go to "

No Water Fill Test

" page 2.

09

(Not Used)

10

Low rpm
unbalanced load

Never reached 400
rpm due to an
unbalanced load

Go to "

Wet Clothes

" page 2.

11

Non-volatile
memory error

Difficulty in reading
memory

1. Go to "

Clearing Diagnostic Code

 "

page 9.
2. Unplug and replug in power cord

washer at power supply outlet

3. If a condition still exists, replace

machine control board.

12-14 (Not Used)

15

Stuck key

A key is sensed to be

pressed for more than
75 seconds, the key

shall be assumed to

be stuck

Replace console/membrane switch.

16

High speed not

achieved due to

high motor torque

Speed never went over

400 rpm during a main
wash cycle because
the maximum torque
was seen for too long

Go to "

Wet Clothes

" page 2.

17

Door actuator

switch was not
seen open since
the last final spin

The door has not been
opened after a
complete wash cycle.

Will display "

od

"

Check for:
- Customer may have tried to repeat

wash cycle without opening door

-Go to "

Door Lock Test

" page 6.

18

Door lock switch

seen open during
cycle

Door lock switch is
read as open with
motor running

- Clear the diagnostic code, page 9.

recheck;

"Go to "

Door Lock Test

" page 6.

Содержание MAH5500B Series

Страница 1: ...trol Test Washer does not tumble during some drains and rinse fills No Water Fill Check to make sure water supply turned on fully Normal water level is only 2 5 to 5 inches inside the spinner Check fo...

Страница 2: ...mperature of the water in the tub This may appear to be significantly warmer cooler than expected Are both faucets on fully Make sure temperature selection is correct Make sure hoses are connected to...

Страница 3: ...ety check the door must be opened at the completion of every cycle nF No fill the machine has tried to fill but cannot See No Water Fill PF Power failure power to the machine has been lost during the...

Страница 4: ...While in quick service cycle the pressing of the hand wash will suspend the machine at this step for 30 minutes until the Hand Wash key is pressed again All LED s will flash on and off while the cycl...

Страница 5: ...e a voltmeter look for 120VAC 60 millisecond pulse to the locking solenoid 7 Press stain cycle to start the motor control output test This will send 120VAC to the motor control board The motor control...

Страница 6: ...machine control board by reading DC voltage between P4 4 and P4 8 If voltage is present at the machine control board check voltage at pressure switch between BU and BR If voltage present at pressure s...

Страница 7: ...n sturdy key Check for hot water flow at the dispenser If no hot water flow check the hot water valve for 120 VAC between OR and WH If 120 VAC is present at the hot valve replace the water valve If 12...

Страница 8: ...p Stain Cycle Motor Control Extra Rinse Unlock Door Sends a pulse every second for 10 seconds Max Extract Lock Door Sends a pulse everysecond for 10 seconds Board Input Test While in service mode pres...

Страница 9: ...ds Go to Wet Clothes page 2 06 Locked rotor Motor not turning after 10 consecutive retry attempts Will display Lr Go to Motor Control Board Output Test page 5 07 Not Used DIAGNOSTIC CODES Number of Cy...

Страница 10: ...in power cord washer at power supply outlet 3 If a condition still exists replace machine control board 12 14 Not Used 15 Stuck key A key is sensed to be pressed for more than 75 seconds the key shal...

Страница 11: ...iled on machine control board Door sense switch is read as open and the door locked switch is read as locked Go to Door Lock Test page 6 22 Door switch seen open during cycle Door switch is read as op...

Страница 12: ...December 2004 12 16025861 2004 Maytag Services WARNING To avoid risk of electrical shock personal injury or death disconnect power to washer before servicing unless testing requires it Wiring Diagram...

Страница 13: ...DE FONTAINE FOUNTAIN LIGHT VOYANT DE FONTAINE FRONT WEIGHT DISPLACEMENT SWITCH CONTACTEUR DE D S QUILIBRE DU POIDS AVANT FUSE FUSIBLE FUSE BLOCK BLOC FUSIBLES FZ LITE SWITCH CONTACTEUR DE VOYANT DU CO...

Страница 14: ...NTERRUPTEUR DE REMPLISSAGE UNIPOLAIRE UNIDIRECTIONNEL STATOR STATOR SUPER COOL TR S FRAIS SUPPLY LINE CONDUITE D ALIMENTATION SYSTEM RELAY RELAIS DE SYST ME TAN TN BRONZE BR TCO MAG TCO MAG TERM BLOCK...