December 2004 10
16025861
©2004 Maytag Services
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing,
unless testing requires it.
Troubleshooting
Diag.
Code
Description
Trigger
Action to be Taken
08
Water sensor level
fault
The low water level is
not satisfied before the
high water level
contacts are opened
in the pressure switch
Go to "
No Water Fill Test
" page 2.
09
(Not Used)
10
Low rpm
unbalanced load
Never reached 400
rpm due to an
unbalanced load
Go to "
Wet Clothes
" page 2.
11
Non-volatile
memory error
Difficulty in reading
memory
1. Go to "
Clearing Diagnostic Code
"
page 9.
2. Unplug and replug in power cord
washer at power supply outlet
3. If a condition still exists, replace
machine control board.
12-14 (Not Used)
15
Stuck key
A key is sensed to be
pressed for more than
75 seconds, the key
shall be assumed to
be stuck
Replace console/membrane switch.
16
High speed not
achieved due to
high motor torque
Speed never went over
400 rpm during a main
wash cycle because
the maximum torque
was seen for too long
Go to "
Wet Clothes
" page 2.
17
Door actuator
switch was not
seen open since
the last final spin
The door has not been
opened after a
complete wash cycle.
Will display "
od
"
Check for:
- Customer may have tried to repeat
wash cycle without opening door
-Go to "
Door Lock Test
" page 6.
18
Door lock switch
seen open during
cycle
Door lock switch is
read as open with
motor running
- Clear the diagnostic code, page 9.
recheck;
"Go to "
Door Lock Test
" page 6.