Appendix C: Ethernet Termination
Straight-Through Ethernet Cable
For most installations, the Straight-Through Ethernet Cable is used. Terminate the
Ethernet cable according to the diagram below using the T-568B wiring standard for
both ends. One end should already be pre-terminated to the switch or hub.
Figure 83 – Straight-Through Ethernet Cable
RJ-45 Crossover Ethernet Cable
On some occasions, a Crossover Ethernet Cable is required. If you require a cable to
connect two Ethernet devices directly together without a hub or when you connect two
hubs together, you will need to use a crossover cable instead.
Figure 84 – RJ-45 Crossover Ethernet Cable