![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298084.webp)
Apex Classic Setup and Programming Guide v2.2
Page
79
To Cancel the Feed Timers
Apex Display: Control/Status – Feed Cancel or from the Feed Timer
display, push the Cancel button. The Feed Timer will be canceled and all
outlets returned to their normal function as if the Feed Timer was never
invoked.
Web Interface: Status – near the bottom of all the status pages, click the
Feed Cancel button. The Feed Timer will be canceled and all outlets
returned to their normal function as if the Feed Timer was never invoked.
LOGGING
The AquaController Apex periodically saves status information for each activated
probes on the system. This information is used to create graphs and to track the
history of your system. The AquaController Apex will continue to save log entries
until the log memory is full at which time the oldest log entry will be
automatically over-written. The AquaController Apex contains enough log
memory to store over a year of log entries for a typical system.
LOG INTERVAL
The log interval determines how frequently log entries are saved. Setting the log
interval too long can miss important events in the log like temperature or pH
spikes. Setting the interval too short will fill the Apex memory prematurely
preventing the ability to see trends over time. The default log interval is 10
minutes. Acceptable settings are from 1 to 250 minutes.
To change the Log Interval:
Apex Display: Data Log – Log Interval – use the up/down arrows to
change the log interval, push OK to save changes, Exit to cancel changes.
Web Interface: This option is not available from the Web Interface.
DATA LOG
The Data Log displays the raw data collected from each probe with the time
stamp of the measurement. This data can be viewed in 3 ways:
Apex Display: Data Log – Display Log – Displays the data log on the Apex
Display.
Web Interface: XML – XML Datalog – lists the day’s data log in XML
format.