WP Series Specification Sheet
Table 2 - WP Series Specification Sheet
MODEL
WP25211
WP25212
WP25213
Rated Capacity, Permeate*
- Gal/Day
350
700
1000
- Gals/Min
.24
.48
.70
- Cubic Meters/Day
1.3
2.7
3.8
Concentrate Flow (Reject)
- Gals/Min
1.1
1.2
.97
- System Pressure, PSI
100-150
100-150
100-150
- Degrees Celsius/ Degrees F
25/77
25/77
25/77
Pre-Filters
- Sediment Cartridge - 5 micron
1
1
1
- Carbon Cartridge - 10 micron
1
1
1
Pressure Switch Settings
- Low Pressure (for pump protection)
8 PSI
8 PSI
8 PSI