Neomatica ADM35 Скачать руководство пользователя страница 8

Neomatica LLC, Bluetooth sensor ADM35, ADM35H, version 1.1 dd 02.07.2021

 

8

 

operation. The signal strength from -85 dBm up to 90 dBm is considered as sufficient for operation, 

but problems may occur at a slight deterioration of conditions. 

 

4.1.3 Setting

 

 

The  sensor  is  supplied  with  optimal  factory  settings.  If  the  factory  settings  are  suitable  for 

the  task,  no  sensor  configuration  is  required.  You  can  immediately  connect  the  sensor  to  the 

tracker. 

By default, the data transfer period is set to 15 seconds and all sensors are active, except 

for the Hall sensor. If you need to use a Hall sensor, you should enable the corresponding option. 

 

Recording to the archive is disabled by default, to use this function, you  should enable the 

corresponding option and configure the frequency of recording to the archive. 

The readings of all active sensors are recorded in the archive. 

 

Main sensor parameters available for configuration: 

  Mode of data transfer 

This parameter determines the technology via which the data will be transmitted. Bluetooth 

Long Range technology allows increasing the distance from the sensor to the receiving device and 

to increase the reliability. The receiving device should support data receipt via such technology.  

BLE  technology  allows  transferring  data  over  shorter  distances.  Such  a  technology  is 

supported by most devices. Mode BLE is given by default. 

 

  Data tranmission period 

This  parameter  determines  transmission  frequency  of  the  data  via  the  Bluetooth  LE  radio 

channel, as well as the frequency of measurements. The measurement is performed  by all active 

detectors  before  sending  the  readings.  In  the  intervals  between  the  measurement  and  sending 

readings, the sensor is in a sleep mode. 

Increase  of  the  transmission  period  extends  the  battery  life,  but  reduces  the  frequency  of 

readings  update,  and  also  increases  the  time  switch  to  the  setting  mode.  By  reducing  this 

parameter you decrease the battery life. The recommended value is 15 seconds. 

 

 

Hall sensor

 

Activation / deactivation of the Hall sensor 

It  is  recommended  to  activate  this  sensor  only  when  it  is  necessary  to  use  it,  because  its 

activation  leads  to  an  increase  in  energy  consumption.  When  the  Hall  sensor  is  activated,  an 

extraordinary exit from the sleep state and sending readings may happen.  

 

Содержание ADM35

Страница 1: ......

Страница 2: ...elated tracker from the devices manufactured by Neomatica LLC The Operation manual is designed for professionals who have familiarized themselves with the rules of repair and installation works execut...

Страница 3: ...10 4 2 3 Report generation in ADM BLE Configurator application 12 4 2 4 Firmware update of the sensor 13 4 3 Using the sensor together with the trackers DM007 and ADM333 that contains BLE interface 13...

Страница 4: ...cal features The ADM35 model figure 1 measures temperature more accurately its temperature measuring element has higher protection from moisture but the model does not contain a measuring element to m...

Страница 5: ...iver sensitivity 96 dBm Data exchange technology Bluetooth Low Energy BLE Bluetooth Low Energy Long Range BLE Long Range Coverage in the mode of BLE up to 100 m in line of sight Coverage in the mode o...

Страница 6: ...pe of Hall detector discrete omnipolar Frequency range of radio interface 2400 2483 5 Hz Transmitter power up to 8 dBm Receiver sensitivity 96 dBm Data exchange technology Bluetooth Low Energy BLE Blu...

Страница 7: ...correspond to the operating conditions of the sensor If you need to fasten more tightly the methods listed above can be combined The transparent lid of the sensor should be clean Impurities present o...

Страница 8: ...Range technology allows increasing the distance from the sensor to the receiving device and to increase the reliability The receiving device should support data receipt via such technology BLE techno...

Страница 9: ...s is due to Google requirements for applications that provide data exchange with BLE devices since BLE technology includes positioning by BLE beacons You also need permission for the access of photos...

Страница 10: ...ination Humidity only for ADM35H Hall element Battery voltage Firmware version RSSI level of received radio signal The time passed since the last data message was received LR data received by Bluetoot...

Страница 11: ...r To save battery power it is not recommended to activate this detector if it is not planned to be used Humidity sensor Enabling or disabling the humidity sensor Illumination sensor Enabling or disabl...

Страница 12: ...in ADM BLE Configurator application Wait until the sensor is detected and see the date and time of the last data synchronization Only the synchronized data will be recorded in the report Synchronize t...

Страница 13: ...he trackers DM007 and ADM333 that contains BLE interface 4 3 1 Method of sensors catching The sensor is catched on the tracker side By default the sensor is configured to measure temperature humidity...

Страница 14: ...in the end of the list BLESENSOR 0 clear the list BLESENSOR display the list of addresses added in the tracker Example of commands entering BLESENSOR 0 0C61CFEF5E31 add the address 0C 61 CF EF 5E 31 i...

Страница 15: ...without filters BLEAUTOCATCH automatic search of all supported BLE sensors without filters BLEAUTOCATCH 0 stop current search 4 3 5 Getting information from the sensors caught BLESENSORINFO command a...

Страница 16: ...40 and relative humidity at most 85 After transportation of the sensors in sub zero temperatures they should be stored at room temperature within 24 hours 6 Warranty The manufacturer guarantees the p...

Страница 17: ...d individual package is possible 8 Disposal Disposal of the sensor and discharged battery is performed according to national and local norms and requirements 9 Scope of supply Device name Quantity Com...

Страница 18: ...o avoid problems we recommend at first to update the tracker to the latest available firmware version Connect the Teltonika device to the Configurator by any convenient way In the left menu find the i...

Страница 19: ...7 2021 19 In the MAC field enter without entering a colon the MAC address of the ADM sensor from which the tracker will receive and process the data The table of data received from ADM sensor should b...

Страница 20: ...rver 2 calculation formulas are used for two ranges of incoming values For the range of values from 0 to 32767 use the formula X 0 01 For the range of values from 32768 to 65535 use the formula X 0 01...

Страница 21: ...ystem language 4 If connection failed try to connect again The connection will be set up as soon as the sensor sends the first Advertising message once per 15 seconds by default 5 After connection on...

Страница 22: ...If the command is read correctly the command name itself will be duplicated in TX Characteristic without a parameter sf x activation of additional sensor functions Only the Hall element To enable it s...

Отзывы: