1.) LINE CLEANING: Before
disassembling the vaccinator for
cleaning, clean the line. Partially fill a
sink or small container with hot, soapy
water. Hold the remote draw-off spike
underneath the water in one hand while
holding the vaccinator in the other.
Continuously squeeze the vaccinator,
pumping water through it until clean.
To rinse, repeat with clean water.
2.) BARREL REMOVAL: Unscrew the
needle nut (A) from the barrel (B). Next,
unscrew the barrel, turning it by the barrel
flange (C) remove enitre barrel from
vaccinator. Wash the all parts in hot, soapy
water, then rinse. Use the supplied brush to
remove any remaining contaminants from
barrel.
3.) HANDLE CLEANING: Remove the feedline from the vaccinator. At this
point, the remaining handle assembly(D) should be washed or allowed to soak in
hot soapy water, then rinsed and allowed to dry. Before reinstalling the barrel
assembly, apply 1 or 2 drops of food-grade lubricant to the piston o-ring (E).
Squeeze the handle to move the piston forward, making it more accessable.
4.) REASSEMBLY: Reinstall the needle (A) nut onto the barrel (B) and resintall
barrel onto handle assembly-hand tighten only.
!!CAUTION!! DO NOT OVER TIGHTEN NEEDLE NUT OR BARREL! FINGER
TIGHTEN ONLY! OVERTIGHTENING CAN CAUSE BARREL BREAKAGE!
DO NOT PLACE ANY PART OF THE VACCINATOR IN A MICROWAVE OVEN
OR NEAR A HEAT SOURCE!
*PRIMA TECH
CLEANING KIT
PART# 341013.*
CLEANING INSTRUCTIONS
UNI-LOCK ASSEMBLY INSTRUCTIONS
1. Place rubber flat
washer onto spike.
Spike
Rubber flat
washer
2. Place spike
collar onto
bottle.
Spike Collar
4. Attach
spike collar
lock to spike
collar by
rotating
clockwise.
Spike Collar
Lock
3. Insert
spike into
bottle.
5. Insert
tubing
onto spike
hose barb.
Flexible
Tubing
6. Attach syringe to free end of
tubing. The assembly is ready
for use.
Prima Tech instruction form #340894-A